SciELO - Scientific Electronic Library Online

 
vol.27 issue3Effectiveness and safety profile of short-term NSAIDs protocols in dental implantology. A systematic review of clinical evidenceIn Vitro analysis of marginal sealing using light curing techniques on aged and unaged composite resins author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Odovtos International Journal of Dental Sciences

On-line version ISSN 2215-3411Print version ISSN 1659-1046

Abstract

MENDEZ-GONZALEZ, María Verónica et al. Influence of thermal treatment on fracture due to cyclic fatigue of rotary files. Odovtos [online]. 2025, vol.27, n.3, pp.86-100. ISSN 2215-3411.  http://dx.doi.org/10.15517/ijds.2025.65254.

The objective of this study aimed to assess the cyclic fatigue fracture of ZenFlexTM, ProTaper GoldTM, and HyFlexTM. EDM rotary files in simulated curved canals, along with evaluating their physicochemical properties and thermal behavior. A total of 69 instruments from three different NiTi rotary file systems were utilized: ProTaper GoldTM (08/25), HyflexTM EDM (08/25), and ZenflexTM (06/25). The analysis consisted of four phases: Phase 1 involved SEM observation to detect manufacturing defects; Phase 2 focused on cyclic fatigue-induced fracture in a curved canal with a 60° radius of curvature of 2 mm and a diameter of 1.5 mm; Phase 3 encompassed SEM observation of the fractured fragment and obtaining a fractographic study; Phase 4 included physicochemical characterization, such as equiatomic relationships by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES), phase transformation by DSC, crystalline structure by X-ray diffraction, and morphological analysis by SEM. Microcracks and defects were observed on cutting edges of ZenFlexTM and ProTaper GoldTM files. The mean cycles to fracture were 2814.50±161.58, 2649.94±120.93, and 1362.89±88.33 for HyFlexTM, ZenFlexTM, and ProTaper GoldTM, respectively. Moreover, different phase transition temperatures were noted, with ZenFlexTM in the austenite phase, ProTaper GoldTM in martensite, and HyFlexTM in the R phase at room temperature, as corroborated by X-ray diffraction. Additionally, a quasi-equimolar relationship was observed for the different systems, with ZenFlexTM exhibiting a reduced helical angle, followed by HyFlexTM and ProTaper GoldTM. ZenFlexTM files demonstrated greater resistance to cyclic fatigue, which appeared to be attributed to their physicochemical properties, heat treatment, and design.

Keywords : Austenite; Martensite; Cyclic fatigue; HyFlexTM EDM; ZenFlexTM; Protaper GoldTM.

        · abstract in Spanish     · text in English     · English ( pdf )