<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>2215-3411</journal-id>
<journal-title><![CDATA[Odovtos International Journal of Dental Sciences]]></journal-title>
<abbrev-journal-title><![CDATA[Odovtos]]></abbrev-journal-title>
<issn>2215-3411</issn>
<publisher>
<publisher-name><![CDATA[Facultad de Odontología. Universidad de Costa Rica]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S2215-34112017000100051</article-id>
<article-id pub-id-type="doi">10.15517/ijds.v0i0.27288</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[Automatic Electronic Device Used for the Evaluation of Cyclic-Fatigue Resistance of Nickel-Titanium Instruments]]></article-title>
<article-title xml:lang="es"><![CDATA[Dispositivo electrónico automático usado para la evaluación de la resistencia a la fatiga cíclica de instrumentos de Niquel-Titanio]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Gaitán-Fonseca]]></surname>
<given-names><![CDATA[Cesar]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Lara-Alvarado]]></surname>
<given-names><![CDATA[Edith]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Flores-Reyes]]></surname>
<given-names><![CDATA[Héctor]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pozos-Guillén]]></surname>
<given-names><![CDATA[Amaury]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Méndez-González]]></surname>
<given-names><![CDATA[Verónica]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad Autónoma de Zacatecas Área de Ciencias de la Salud ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>MX</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Universidad Autónoma de San Luis Potosí Facultad de Estomatología ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>MX</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,Universidad Autónoma de San Luis Potosí Laboratorio de Ciencias Básicas Facultad de Estomatología]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>MX</country>
</aff>
<aff id="Af4">
<institution><![CDATA[,Universidad Autónoma de San Luis Potosí Facultad de Estomatología ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>MX</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2017</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2017</year>
</pub-date>
<volume>19</volume>
<numero>1</numero>
<fpage>51</fpage>
<lpage>58</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_arttext&amp;pid=S2215-34112017000100051&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_abstract&amp;pid=S2215-34112017000100051&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_pdf&amp;pid=S2215-34112017000100051&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[AbstractThe aim of this study was to evaluate the cyclic-fatigue fracture of different Nickel-Titanium motor-driven rotary instruments (ProTaper® Universal, ProFile®, and Mtwo® systems) in artificial canals by means of an Automatic Electronic Device (AED). The study was performed using NickelTitanium instruments 25/0.06 evaluated in canals with a 45-degree curvature and 2-mm radius. The analyses evaluated two parameters: fracture by cyclic fatigue, and time of fracture; in addition, the length of separated fragment was evaluated. Medians and range values were calculated for each group. Data were analyzed by the Kruskall-Wallis and Mann-Whitney U tests to determine statistical difference. The ProFile motor-driven rotator system exhibited highest resistance to fracture due to cyclic fatigue and highest fracture time compared with the ProTaper and Mtwo systems (p &lt;0.05). The equipment proposed in this study (AED) demonstrated efficiency for recording information, automation, scheduled work times and durations, cycle number, time of fracture, pressure changes and, principally control of the human factor.]]></p></abstract>
<abstract abstract-type="short" xml:lang="es"><p><![CDATA[ResumenEl objetivo del presente estudio fue evaluar la fractura a la fatiga cíclica de diferentes instrumentos rotatorios de Niquel-Titanio (sistemas ProTaper® Universal, ProFile® y Mtwo®) en conductos artificiales por medio de un Dispositivo Electrónico Automático (DEA). Se usaron instrumentos de Niquel-Titanio 25/0.06, los cuales se evaluaron en conductos con una curvatura de 45 grados y 2 milímetros de radio. Se analizaron dos parámetros: Fractura a la fatiga cíclica y tiempo a la fractura; además se evaluó la longitud del fragmento separado. Medianas y rangos fueron calculados para cada uno de los grupos. Los resultados fueron analizados por las pruebas de Kruskall-Wallis y U de Mann-Whitney para determinar diferencias estadísticas. El Sistema ProFile mostró una mayor resistencia y tiempo a la fractura en comparación con los sistemas ProTaper y Mtwo (p &lt;0.05). El equipo propuesto en este estudio (DEA) demostró eficiencia para el registro de la información, tiempos de trabajo y duración, número de ciclos, tiempo a la fractura, cambios en la presión y principalmente control del factor humano.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[Cyclic-fatigue]]></kwd>
<kwd lng="en"><![CDATA[Nickel-Titanium instruments]]></kwd>
<kwd lng="en"><![CDATA[Automatic electronic device]]></kwd>
<kwd lng="en"><![CDATA[Rotary instruments]]></kwd>
<kwd lng="en"><![CDATA[ProTaper® Universal System]]></kwd>
<kwd lng="en"><![CDATA[ProFile® System]]></kwd>
<kwd lng="en"><![CDATA[Mtwo® System.]]></kwd>
<kwd lng="es"><![CDATA[Fatiga cíclica]]></kwd>
<kwd lng="es"><![CDATA[Instrumentos Niquel-Titanio]]></kwd>
<kwd lng="es"><![CDATA[Dispositivo electrónico automático]]></kwd>
<kwd lng="es"><![CDATA[Instrumentos rotatorios]]></kwd>
<kwd lng="es"><![CDATA[Sistema ProTaper® Universal]]></kwd>
<kwd lng="es"><![CDATA[Sistema ProFile®]]></kwd>
<kwd lng="es"><![CDATA[Sistema Mtwo®]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Shaping ability of ProTaper NEXT, ProTaper Universal and iRace files in simulated S-shaped canals]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hiran-Us]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Pimkhaokham]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Sawasdichai]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Ebihara]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Suda]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<source><![CDATA[Aust Endod J]]></source>
<year>2016</year>
<volume>42</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>32-6</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Cyclic fatigue resistance of newly manufactured rotary nickel titanium instruments used in different rotational directions]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gambarini]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Gergi]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Grande]]></surname>
<given-names><![CDATA[N. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Osta]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
<name>
<surname><![CDATA[Plotino]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Testarelli]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<source><![CDATA[Aust Endod J]]></source>
<year>2013</year>
<volume>39</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>151-4</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Effect of reciprocation usage of nickeltitanium rotary files on the cyclic fatigue resistance]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[Hwang]]></surname>
<given-names><![CDATA[Y. J.]]></given-names>
</name>
<name>
<surname><![CDATA[You]]></surname>
<given-names><![CDATA[S. Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[H. C]]></given-names>
</name>
</person-group>
<source><![CDATA[Aust Endod J]]></source>
<year>2013</year>
<volume>39</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>146-50</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Cyclic fatigue resistance of D-RaCe, ProTaper, and Mtwo nickel-titanium retreatment instruments after immersion in sodium hypochlorite]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Topçuo&#287;lu]]></surname>
<given-names><![CDATA[H. S.]]></given-names>
</name>
<name>
<surname><![CDATA[Pala]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Akt&#305;]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Düzgün]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Topçuo&#287;lu]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<source><![CDATA[Clin Oral Investig]]></source>
<year>2016</year>
<volume>20</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1175-9</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Cyclic fatigue on endodontic nickel titanium rotary instruments: static and dynamic tests]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[U. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[B. S.]]></given-names>
</name>
<name>
<surname><![CDATA[Shih]]></surname>
<given-names><![CDATA[C. T.]]></given-names>
</name>
<name>
<surname><![CDATA[Lan]]></surname>
<given-names><![CDATA[W. H.]]></given-names>
</name>
<name>
<surname><![CDATA[Lin]]></surname>
<given-names><![CDATA[C. P]]></given-names>
</name>
</person-group>
<source><![CDATA[J. Endod.]]></source>
<year>2002</year>
<volume>28</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>448-51</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Fatigue resistance of engine-driven rotary nickel-titanium endodontic instruments]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chaves Craveiro de Melo]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Guiomar de Azevedo Bahia]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Lopes Buono]]></surname>
<given-names><![CDATA[V. T]]></given-names>
</name>
</person-group>
<source><![CDATA[J. Endod.]]></source>
<year>2002</year>
<volume>28</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>765-9</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Comparision of cycle fatigue resistance of novel nickeltitanium rotary instruments]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Capar]]></surname>
<given-names><![CDATA[I. S.]]></given-names>
</name>
<name>
<surname><![CDATA[Ertas]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Arslan]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<source><![CDATA[Aust Endod J]]></source>
<year>2015</year>
<volume>41</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>24-8</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Cyclic fatigue analisis of Reciproc R25® instruments with different kinematics]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Arslan]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Alsancak]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Do&#287;anay]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Karata&#351;]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Çapar]]></surname>
<given-names><![CDATA[I. D.]]></given-names>
</name>
<name>
<surname><![CDATA[Ertas]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<source><![CDATA[Aust Endod J]]></source>
<year>2016</year>
<volume>42</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>22-4</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Relationship of broken root canal instruments to endodontic case prognosis: a clinical investigation]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Crump]]></surname>
<given-names><![CDATA[M. C.]]></given-names>
</name>
<name>
<surname><![CDATA[Natkin]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<source><![CDATA[J. Am Dent Assoc]]></source>
<year>1970</year>
<volume>80</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1341-7</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Procedural errors with the use of nickeltitanium rotary instruments in undergraduate endodontics]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pettiette]]></surname>
<given-names><![CDATA[M. T.]]></given-names>
</name>
<name>
<surname><![CDATA[Conner]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Trope]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[J. Endod.]]></source>
<year>2002</year>
<volume>28</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>259</page-range></nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Incidence of rotary ProFile instrument fracture and potential for by passing in vivo]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Al-Fouzan]]></surname>
<given-names><![CDATA[K. S]]></given-names>
</name>
</person-group>
<source><![CDATA[Int Endod J]]></source>
<year>2003</year>
<volume>36</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>864 -8647</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Cyclic fatigue of ProFile rotary instruments after clinical use]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yared]]></surname>
<given-names><![CDATA[G. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Bou Dagher]]></surname>
<given-names><![CDATA[F. E.]]></given-names>
</name>
<name>
<surname><![CDATA[Machtou]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<source><![CDATA[Int Endod J]]></source>
<year>2000</year>
<volume>33</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>204-7</page-range></nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Cyclic fatigue resistance and threedimensional analysis of instruments from two nickel- titanium rotary systems]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Grande]]></surname>
<given-names><![CDATA[N. M]]></given-names>
</name>
<name>
<surname><![CDATA[Plotino]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Pecci]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Bedini]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Malagnino]]></surname>
<given-names><![CDATA[V. A]]></given-names>
</name>
<name>
<surname><![CDATA[Somma]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<source><![CDATA[Int Endod J]]></source>
<year>2006</year>
<volume>39</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>755-63</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Fatigue testing of a NiTi rotary instrument. Part 1: strain-life relationship]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cheung]]></surname>
<given-names><![CDATA[G. S.]]></given-names>
</name>
<name>
<surname><![CDATA[Darvell]]></surname>
<given-names><![CDATA[B. W]]></given-names>
</name>
</person-group>
<source><![CDATA[Int Endod J]]></source>
<year>2007</year>
<volume>40</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>612-8</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Structural and functional fatigue of NiTi shape memory alloys]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Eggeler]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Hornbogen]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Yawny]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Heckmann]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Wagner]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Mater Sci Eng A]]></source>
<year>2004</year>
<volume>378</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>24-33</page-range></nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Defects in rotary nickeltitanium files after clinical use]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sattapan]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Nervo]]></surname>
<given-names><![CDATA[G. J.]]></given-names>
</name>
<name>
<surname><![CDATA[Palamara]]></surname>
<given-names><![CDATA[J. E.]]></given-names>
</name>
<name>
<surname><![CDATA[Messer]]></surname>
<given-names><![CDATA[H. H]]></given-names>
</name>
</person-group>
<source><![CDATA[J. Endod.]]></source>
<year>2000</year>
<volume>26</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>161-5</page-range></nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[A pressure sensitive periodontal probe]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gabathules]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Hassell]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<source><![CDATA[Helv Odontol Acta]]></source>
<year>1971</year>
<volume>15</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>114-7</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[A comparison of canal preparations in straight and curved root canals]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schneider]]></surname>
<given-names><![CDATA[San W]]></given-names>
</name>
</person-group>
<source><![CDATA[Oral Surg Oral Med Oral Pathol]]></source>
<year>1971</year>
<volume>32</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>271-5</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[An overview of nickeltitanium alloys used in dentistry]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Thompson]]></surname>
<given-names><![CDATA[S. A]]></given-names>
</name>
</person-group>
<source><![CDATA[Int Endod J]]></source>
<year>2000</year>
<volume>33</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>297-310</page-range></nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[The principles of techniques for cleaning root canals]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Young]]></surname>
<given-names><![CDATA[G. R.]]></given-names>
</name>
<name>
<surname><![CDATA[Parashos]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Messer]]></surname>
<given-names><![CDATA[H. H]]></given-names>
</name>
</person-group>
<source><![CDATA[Aust Endod J]]></source>
<year>2007</year>
<volume>52</volume>
<numero>^s1 Suppl</numero>
<issue>^s1 Suppl</issue>
<supplement>1 Suppl</supplement>
<page-range>S52-63</page-range></nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Cyclic fatigue of nickeltitanium rotary instruments after clinical use with low- and high-torque endodontic motors]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gambarini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<source><![CDATA[J. Endod.]]></source>
<year>2001</year>
<volume>27</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>772-4</page-range></nlm-citation>
</ref>
<ref id="B22">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Dynamic and cyclic fatigue of engine driven rotary nickel-titanium endodontic instruments]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Haikel]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Serfaty]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Bateman]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Singer]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Allemann]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<source><![CDATA[J. Endod.]]></source>
<year>1999</year>
<volume>25</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>434-40</page-range></nlm-citation>
</ref>
<ref id="B23">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Cyclic fatigue of different nickel-titanium endodontic rotary instruments]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tripi]]></surname>
<given-names><![CDATA[T. R.]]></given-names>
</name>
<name>
<surname><![CDATA[Bonaccorso]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Condorelli]]></surname>
<given-names><![CDATA[G. G]]></given-names>
</name>
</person-group>
<source><![CDATA[Oral Surg Oral Med Oral Pathol Oral Radiol Endod]]></source>
<year>2006</year>
<volume>102</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>e106-14</page-range></nlm-citation>
</ref>
<ref id="B24">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instruments]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schäfer]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Erler]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Dammaschke]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<source><![CDATA[Int Endod J]]></source>
<year>2006</year>
<volume>39</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>196-202</page-range></nlm-citation>
</ref>
<ref id="B25">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Effect of cross-sectional area of 6 nickel-titanium rotary instruments on the fatigue fracture under cyclic flexural stress: A fractographic analysis]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Soo-Youn]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[So-Ram]]></surname>
<given-names><![CDATA[O.]]></given-names>
</name>
<name>
<surname><![CDATA[Yoon]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[SangMin]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Kee-Yeon]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<source><![CDATA[J. Korean Acad Conserv Dent]]></source>
<year>2009</year>
<volume>34</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>424-9</page-range></nlm-citation>
</ref>
<ref id="B26">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[A Review of cyclic fatigue testing of nickel-titanium rotary instruments]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Plotino]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Grande]]></surname>
<given-names><![CDATA[N. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Cordaro]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Testarelli]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Gambarini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<source><![CDATA[J. Endod.]]></source>
<year>2009</year>
<volume>35</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>401-3</page-range></nlm-citation>
</ref>
<ref id="B27">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Cyclic fatigue of different nickel-titanium rotary instruments: A comparative study]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Testarelli]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Grande]]></surname>
<given-names><![CDATA[N. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Plotino]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Lendini]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Pongione]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[De Paolis]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<source><![CDATA[Open Dent J]]></source>
<year>2009</year>
<volume>3</volume>
<page-range>55-8</page-range></nlm-citation>
</ref>
<ref id="B28">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gambarin]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Grande]]></surname>
<given-names><![CDATA[N. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Plotino]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Somma]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Garala]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[J. Endod.]]></source>
<year>2008</year>
<volume>34</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>1003-5</page-range></nlm-citation>
</ref>
<ref id="B29">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Torsional and cyclic fatigue resistance of a new nickel-titanium instrument manufactured by electrical discharge machining]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pedullà]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Lo Savio]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Boninelli]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Plotino]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Grande]]></surname>
<given-names><![CDATA[N. M.]]></given-names>
</name>
<name>
<surname><![CDATA[La Rosa]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Rapisarda]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<source><![CDATA[J. Endod.]]></source>
<year>2016</year>
<volume>42</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>156-9</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>