<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>2215-3411</journal-id>
<journal-title><![CDATA[Odovtos International Journal of Dental Sciences]]></journal-title>
<abbrev-journal-title><![CDATA[Odovtos]]></abbrev-journal-title>
<issn>2215-3411</issn>
<publisher>
<publisher-name><![CDATA[Facultad de Odontología. Universidad de Costa Rica]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S2215-34112021000100064</article-id>
<article-id pub-id-type="doi">10.15517/ijds.2020.41442</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Precisión de los sistemas de impresión digital intraoral en odontología restauradora: Una revisión de la literatura]]></article-title>
<article-title xml:lang="en"><![CDATA[Accuracy of Intraoral Digital Impression Systems in Restorative Dentistry: A Review of the Literature]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Medina-Sotomayor]]></surname>
<given-names><![CDATA[Priscilla]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ordóñez]]></surname>
<given-names><![CDATA[Paola]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ortega]]></surname>
<given-names><![CDATA[Gabriela]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad Católica de Cuenca Facultad de Odontología ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Ecuador</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2021</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2021</year>
</pub-date>
<volume>23</volume>
<numero>1</numero>
<fpage>64</fpage>
<lpage>75</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_arttext&amp;pid=S2215-34112021000100064&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_abstract&amp;pid=S2215-34112021000100064&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_pdf&amp;pid=S2215-34112021000100064&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Abstract: La impresión intraoral permite al odontólogo obtener directamente los datos de las piezas dentales que se requiera rehabilitar, otorgándole mayor precisión y eliminando así de la fase clínica la toma de impresión y la fabricación del modelo, aspectos sensibles a errores. El objetivo de la presente revisión es identificar el sistema de impresión digital intraoral más preciso y además identificar los factores que afectan a la precisión de esta en odontología restauradora. Mediante una revisión bibliográfica con búsqueda en las bases de datos de PubMed y Embase se obtuvieron 153 artículos, luego de la evaluación cualitativa se incluyeron en la revisión 14 que cumplieron con los criterios de inclusión y exclusión. Se determinó que la experiencia del dentista, la convergencia en la preparación dental y la terminación cervical son determinantes al momento de la toma de impresión digital, sin embargo, el uso o no de polvo no es relevante. El sistema de impresión digital Lava C.O.S., iTero y True definition son los más precisos dependiendo siempre del tipo de rehabilitación a realizar.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract: Digital impresión allows the dentist to directly obtain the data of the dental pieces that neet to be rehabilitated, giving it greater precisión and thus eliminating the impression and manufacturing of the dental model, error-sensitive aspects of the clinical phase. The aim of this review is to identify the most accurate intraoral digital impression system and identifiy the factors that affect the accuracy in the restorative dentistry. Through a bibliographic review with search in PubMed and Embase databases, 153 articles were obtained, after qualitative evaluation they were included in the revisión 14 that met the inclusion and exclusion criteria. It was determined that the experience of the dentist, the convergence in the dental preparation and the cervical termination are decisive at the accuracy of the digital impression, however, the use or not of dust is not relevant. The Lava C.O.S., iTero and True definition are the most accurate always depending on the type of rehabilitation to be performed.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Impresión digital]]></kwd>
<kwd lng="es"><![CDATA[Escáner intraoral]]></kwd>
<kwd lng="es"><![CDATA[Técnica impresión]]></kwd>
<kwd lng="es"><![CDATA[Precisión]]></kwd>
<kwd lng="en"><![CDATA[Digital impressions]]></kwd>
<kwd lng="en"><![CDATA[Intraoral scanner]]></kwd>
<kwd lng="en"><![CDATA[Impression technique]]></kwd>
<kwd lng="en"><![CDATA[Precision]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Birnbaum]]></surname>
<given-names><![CDATA[N. S.]]></given-names>
</name>
<name>
<surname><![CDATA[Aaronson]]></surname>
<given-names><![CDATA[H. B.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Dental impressions using 3D digital scanners: virtual becomes reality]]></article-title>
<source><![CDATA[Compend Contin Educ Dent]]></source>
<year>2008</year>
<volume>29</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>494-498-505</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zarauz Yáñez]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Pradíes Ramiro]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[I U. C. de M. F. de O. D.]]></surname>
<given-names><![CDATA[de E]]></given-names>
</name>
</person-group>
<source><![CDATA[Estudio comparativo &#8220;in vivo&#8221; de un sistema de impresión convencional con elastómeros vs. un sistema de impresión digital (ITERO): Trabajo de investigación]]></source>
<year>2012</year>
<publisher-loc><![CDATA[España ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brawek]]></surname>
<given-names><![CDATA[P. K.]]></given-names>
</name>
<name>
<surname><![CDATA[Wolfart]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Endres]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Kirsten]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Reich]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[The clinical accuracy of single crowns exclusively fabricated by digital workflow the comparison of two systems]]></article-title>
<source><![CDATA[Clin Oral Investig]]></source>
<year>2013</year>
<volume>17</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>2119-25</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[da Costa]]></surname>
<given-names><![CDATA[J. B.]]></given-names>
</name>
<name>
<surname><![CDATA[Pelogia]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Hagedorn]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Ferracane]]></surname>
<given-names><![CDATA[J. L.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Evaluation of different methods of optical impression making on the marginal gap of onlays created with CEREC 3D]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2010</year>
<volume>35</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>324-9</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Logozzo]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Zanetti]]></surname>
<given-names><![CDATA[E. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Franceschini]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Kilpelä]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Mäkynen]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Recent advances in dental optics. Part I: 3D intraoral scanners for restorative dentistry]]></article-title>
<source><![CDATA[Opt Lasers Eng]]></source>
<year>2014</year>
<volume>54</volume>
<numero>0</numero>
<issue>0</issue>
<page-range>203-21</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Quaas]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Rudolph]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Luthardt]]></surname>
<given-names><![CDATA[R. G.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Direct mechanical data acquisition of dental impressions for the manufacturing of CAD/ CAM restorations]]></article-title>
<source><![CDATA[J Dent]]></source>
<year>2007</year>
<volume>35</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>903-8</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dehurtevent]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Robberecht]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Behin]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Influence of dentist experience with scan spray systems used in direct CAD/CAM impressions]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2015</year>
<volume>113</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>17-21</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Miyazaki]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Hotta]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Kunii]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Kuriyama]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Tamaki]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A review of dental CAD/CAM: current status and future perspectives from 20 years of experience]]></article-title>
<source><![CDATA[Dent Mater J]]></source>
<year>2009</year>
<volume>28</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>44-56</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Güth]]></surname>
<given-names><![CDATA[J. F.]]></given-names>
</name>
<name>
<surname><![CDATA[Keul]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Stimmelmayr]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Beuer]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Edelhoff]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Accuracy of digital models obtained by direct and indirect data capturing]]></article-title>
<source><![CDATA[Clin Oral Investig]]></source>
<year>2013</year>
<volume>17</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>1201-8</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Seelbach]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Brueckel]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Wöstmann]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Accuracy of digital and conventional impression techniques and workflow]]></article-title>
<source><![CDATA[Clin Oral Investig]]></source>
<year>2013</year>
<volume>17</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>1759-64</page-range></nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ng]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Ruse]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Wyatt]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A comparison of the marginal fit of crowns fabricated with digital and conventional methods]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2014</year>
<volume>112</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>555-60</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Syrek]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Reich]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Ranftl]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Klein]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Cerny]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Brodesser]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling]]></article-title>
<source><![CDATA[J Dent]]></source>
<year>2010</year>
<volume>38</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>553-9</page-range></nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tidehag]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Ottosson]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Sjögren]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Accuracy of Ceramic Restorations Made Using an In-office Optical Scanning Technique: An In Vitro Study]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2013</year>
<page-range>308-16</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Almeida e Silva]]></surname>
<given-names><![CDATA[J. S.]]></given-names>
</name>
<name>
<surname><![CDATA[Erdelt]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Edelhoff]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Araújo]]></surname>
<given-names><![CDATA[É.]]></given-names>
</name>
<name>
<surname><![CDATA[Stimmelmayr]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Vieira]]></surname>
<given-names><![CDATA[L. C. C.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques]]></article-title>
<source><![CDATA[Clin Oral Investig]]></source>
<year>2014</year>
<volume>18</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>515-23</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tamim]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Skjerven]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Ekfeldt]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Rønold]]></surname>
<given-names><![CDATA[H. J.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Clinical evaluation of CAD/CAM metal-ceramic posterior crowns fabricated from intraoral digital impressions]]></article-title>
<source><![CDATA[Int J Prosthodont]]></source>
<year>2014</year>
<volume>27</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>331-7.</page-range></nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schaefer]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Decker]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Wittstock]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Kuepper]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Guentsch]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Impact of digital impression techniques on the adaption of ceramic partial crowns in vitro]]></article-title>
<source><![CDATA[J Dent]]></source>
<year>2014</year>
<volume>42</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>677-83</page-range></nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Svanborg]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Skjerven]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Carlsson]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Eliasson]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Karlsson]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Ortorp]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Marginal and internal fit of cobalt-chromium fixed dental prostheses generated from digital and conventional impressions]]></article-title>
<source><![CDATA[Int J Dent]]></source>
<year>2014</year>
<page-range>534382</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Scotti]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Cardelli]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Baldissara]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Monaco]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Clinical fitting of CAD/CAM zirconia single crowns generated from digital intraoral impressions based on active wavefront sampling]]></article-title>
<source><![CDATA[J Dent.]]></source>
<year>2011</year>
<page-range>1-8</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hamza]]></surname>
<given-names><![CDATA[T. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Ezzat]]></surname>
<given-names><![CDATA[H. A.]]></given-names>
</name>
<name>
<surname><![CDATA[El-Hossary]]></surname>
<given-names><![CDATA[M.M. K.]]></given-names>
</name>
<name>
<surname><![CDATA[Katamish]]></surname>
<given-names><![CDATA[H. A. E. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Shokry]]></surname>
<given-names><![CDATA[T. E.]]></given-names>
</name>
<name>
<surname><![CDATA[Rosenstiel]]></surname>
<given-names><![CDATA[S. F.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Accuracy of ceramic restorations made with two CAD/CAM systems]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2013</year>
<volume>109</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>83-7</page-range></nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Reich]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Kern]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Ritter]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Options in virtual 3D, optical-impression-based planning of dental implants]]></article-title>
<source><![CDATA[Int J Comput Dent.]]></source>
<year>2014</year>
<volume>17</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>101-13</page-range></nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Boeddinghaus]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Breloer]]></surname>
<given-names><![CDATA[E. S.]]></given-names>
</name>
<name>
<surname><![CDATA[Rehmann]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Wostmann]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients]]></article-title>
<source><![CDATA[Clin Oral Investig]]></source>
<year>2015</year>
</nlm-citation>
</ref>
<ref id="B22">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Quaas]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Loos]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Rudolph]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Luthardt]]></surname>
<given-names><![CDATA[R.G.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Randomized controlled trial comparing direct intraoral digitization and extraoral digitization after impression taking]]></article-title>
<source><![CDATA[Int J Prosthodont]]></source>
<year>2015</year>
<volume>28</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>30-2</page-range></nlm-citation>
</ref>
<ref id="B23">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nedelcu]]></surname>
<given-names><![CDATA[R. G.]]></given-names>
</name>
<name>
<surname><![CDATA[Persson]]></surname>
<given-names><![CDATA[A. S. K.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Scanning accuracy and precision in 4 intraoral scanners: An in vitro comparison based on 3-dimensional analysis]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2014</year>
<volume>112</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1461-71</page-range></nlm-citation>
</ref>
<ref id="B24">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Medina-Sotomayor]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Pascual-Moscardó]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Camps]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Correction: Accuracy of four digital scanners according to scanning strategy in complete-arch impressions]]></article-title>
<source><![CDATA[PLoS One]]></source>
<year>2018</year>
<volume>13</volume>
<numero>12</numero>
<issue>12</issue>
</nlm-citation>
</ref>
<ref id="B25">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Medina-Sotomayor]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Pascual-Moscardo]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Camps]]></surname>
<given-names><![CDATA[A. I.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Accuracy of 4 digital scanning systems on prepared teeth digitally isolated from a complete dental arch]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2019</year>
<volume>121</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>811-20</page-range></nlm-citation>
</ref>
<ref id="B26">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Medina-Sotomayor]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Pascual-Moscardo]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Camps]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Relationship between resolution and accuracy of four intraoral scanners in complete-arch impressions]]></article-title>
<source><![CDATA[J Clin Exp Dent]]></source>
<year>2018</year>
<volume>10</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>0</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
