<article-id>S1659-42662024000100184</article-id>
<article-id pub-id-type="doi">10.22458/urj.v15i1.5229</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[Implementation of a high dose routine dosimetry in a self-shielded irradiator]]></article-title>
<article-title xml:lang="es"><![CDATA[Implementación de dosimetría de rutina de altas dosis en un irradiador autoblindado]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Vargas-Segura]]></surname>
<given-names><![CDATA[Walter]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rojas-Rojas]]></surname>
<given-names><![CDATA[Laura]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Technological Institute of Costa Rica Physics School ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Costa Rica</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Hospital Mexico Radiotherapy Department ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Costa Rica</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2024</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2024</year>
</pub-date>
<volume>16</volume>
<numero>1</numero>
<fpage>184</fpage>
<lpage>191</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_arttext&amp;pid=S1659-42662024000100184&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_abstract&amp;pid=S1659-42662024000100184&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_pdf&amp;pid=S1659-42662024000100184&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract Introduction: Ionizing radiation is applied in various fields, and dosimetric control guarantees the quality and safety of products during the irradiation process. There is a need for dosimetric calibration procedures in industrial irradiation plants, specifically for self-shielded irradiation systems. Objective: To implement high dose dosimetry in the routine control of irradiated materials within a self- shielded irradiator. Methods: We worked with 32 dosimeters; we divided the dose range used into 8 points and used four RED Perspex dosimeters per point. We measured the specific absorbance for each dosimeter; plotted these values against dose and produced a third- degree polynomial fit as a calibration curve. Results: We obtained the calibration curve with an r2 of 0,9997. The uncertainties due to the dispersion of the dosimeters and the calibration curve were 1,39% and 0,22%, respectively, for a total uncertainty of 4,80%. This uncertainty includes dose determination with a factor coverage (k) equal to 2 for a 95% confidence interval. Conclusion: Perspex RED dosimeters can be used for routine control of irradiated products in a self-shielded irradiator system.]]></p></abstract>
<abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen Introducción: La radiación ionizante se aplica en diversos campos, y el control dosimétrico garantiza la calidad y seguridad de los productos durante el proceso de irradiación. Existe una necesidad de procedimientos de calibración dosimétrica en plantas de irradiación industrial, específicamente para sistemas de irradiación auto blindados. Objetivo: Implementar la dosimetría de altas dosis en el control rutinario de materiales irradiados dentro de un irradiador auto blindado. Métodos: Trabajamos con 32 dosímetros; dividimos el rango de dosis en 8 puntos y utilizamos cuatro dosímetros RED Perspex por punto. Medimos la absorbancia específica de cada dosímetro; trazamos estos valores contra la dosis y produjimos un ajuste polinómico de tercer grado como curva de calibración. Resultados: Obtuvimos la curva de calibración con un r2 de 0,9997. Las incertidumbres debidas a la dispersión de los dosímetros y a la curva de calibración fueron del 1,39% y 0,22%, respectivamente, para una incertidumbre total de 4,80%. Esta incertidumbre incluye la determinación de la dosis, con un factor de cobertura (k) igual a 2 para un intervalo de confianza del 95%. Conclusión: Los dosímetros de Perspex RED sirven para el control rutinario de productos irradiados en un sistema de irradiador auto blindado.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[RED Perspex]]></kwd>
<kwd lng="en"><![CDATA[calibration curve]]></kwd>
<kwd lng="en"><![CDATA[PMMA dosimeters]]></kwd>
<kwd lng="en"><![CDATA[high dose dosimetry]]></kwd>
<kwd lng="en"><![CDATA[self-shielded irradiator]]></kwd>
<kwd lng="en"><![CDATA[dose uncertainty]]></kwd>
<kwd lng="es"><![CDATA[RED Perspex]]></kwd>
<kwd lng="es"><![CDATA[curva de calibración]]></kwd>
<kwd lng="es"><![CDATA[dosímetros PMMA]]></kwd>
<kwd lng="es"><![CDATA[dosimetría altas dosis]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aquino]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Lui]]></surname>
<given-names><![CDATA[C. C.]]></given-names>
</name>
<name>
<surname><![CDATA[Corrêa]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Gamma Radiation Treatment Applied to Microbial Decontamination of Products Derived from Eggs Collected from the Retail Market in São Paulo.]]></article-title>
<source><![CDATA[Arq. Bras. Med. Vet. e Zootec]]></source>
<year>2017</year>
<volume>69</volume>
<page-range>1683-92</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Duarte-Ladeira]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Zacarias-Mesquita A.]]></surname>
<given-names><![CDATA[Tadeuy Pereira M.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Calibrations of Perspex PMMA dosimeter in terms of absorbed dose to water for routine dosimetry at CDTN gamma irradiation laboratory.]]></article-title>
<source><![CDATA[International Journal of Nuclear Energy Science and Technology]]></source>
<year>2016</year>
<volume>9</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>238-48</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Eichholz]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Dosimetry for Food Irradiation.]]></article-title>
<source><![CDATA[Health Physics]]></source>
<year>2003</year>
<volume>84</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>665</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Farkas]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Mohácsi-Farkas]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[History and Future of Food Irradiation.]]></article-title>
<source><![CDATA[Trends in Food Science &amp; Technology]]></source>
<year>2011</year>
<volume>22</volume>
<numero>2- 3</numero>
<issue>2- 3</issue>
<page-range>121-6</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gujarati]]></surname>
<given-names><![CDATA[D. N.]]></given-names>
</name>
<name>
<surname><![CDATA[Porter]]></surname>
<given-names><![CDATA[D. C.]]></given-names>
</name>
</person-group>
<source><![CDATA[Basic Econometrics]]></source>
<year>2009</year>
<edition>5</edition>
<publisher-name><![CDATA[McGraw-Hill Irwin]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="">
<collab>Harwell dosimeters</collab>
<source><![CDATA[Harwell Red 4034 Dosimeters.]]></source>
<year>2022</year>
</nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<collab>International Atomic Energy Agency (IAEA).</collab>
<article-title xml:lang=""><![CDATA[Code of practice for the radiation sterilization of tissue allografts: Requirements for validation and routine control.]]></article-title>
<source><![CDATA[Clinical Applications of Bone Allografts and Substitutes.]]></source>
<year>2005</year>
<page-range>1-55</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="">
<collab>International Atomic Energy Agency (IAEA).</collab>
<source><![CDATA[Guidelines for the Development, Validation and Routine Control of Industrial Radiation Processes.]]></source>
<year>2013</year>
</nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="">
<collab>International Atomic Energy Agency (IAEA).</collab>
<source><![CDATA[Uses of Ionizing Radiation for Tangible Cultural Heritage Conservation.]]></source>
<year>2017</year>
</nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="">
<collab>International Organization for Standardization (ISO).</collab>
<source><![CDATA[Sterilization of Health Care Products - Radiation - Part 1: Requirements for Development, Validation and Routine Control of a Sterilization Process for Medical Devices (ISO 11137-1:2006)]]></source>
<year>2006</year>
</nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="">
<collab>International Organization for Standardization (ISO).</collab>
<source><![CDATA[Standard Practice for Calibration of Routine Dosimetry Systems for Radiation Processing (ISO/ASTM 51261:2013).]]></source>
<year>2013</year>
</nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="">
<collab>International Organization for Standardization (ISO).</collab>
<source><![CDATA[Sterilization of Health Care Products - Radiation - Part 2: Establishing the Sterilization Dose (ISO 11137-2:2013).]]></source>
<year>2013</year>
</nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="">
<collab>International Organization for Standardization (ISO).</collab>
<source><![CDATA[Sterilization of Health Care Products - Radiation - Part 3: Guidance on dosimetric aspects of development, validation and routine control (ISO 11137-3:2017).]]></source>
<year>2017</year>
</nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="">
<collab>International Organization for Standardization (ISO).</collab>
<source><![CDATA[Practice for Use of a Polymethylmethacrylate Dosimetry System (ISO/ASTM 51276:2019).]]></source>
<year>2019</year>
</nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="">
<collab>International Organization for Standardization (ISO).</collab>
<source><![CDATA[Sterilization of Health Care Products - Radiation - Part 4: Guidance on Process Control (ISO/TS 11137-4:2020).]]></source>
<year>2020</year>
</nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="">
<collab>Joint Committee for Guides in Metrology</collab>
<source><![CDATA[Evaluation of Measurement Data-Guide to the Expression of Uncertainty in Measurement.]]></source>
<year>2008</year>
</nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sharpe]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Miller]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<source><![CDATA[NPL Report CIRM 29: Guidelines for the calibration of routine dosimetry systems for use in radiation processing. Teddington: National Physical Laboratory.]]></source>
<year>2009</year>
</nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Whittaker]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Watts]]></surname>
<given-names><![CDATA[M. F.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[The Influence of Dose Rate, Ambient Temperature and Time on the Radiation Response of Harwell PMMA Dosimeters.]]></article-title>
<source><![CDATA[Radiation Physics and Chemistry]]></source>
<year>2001</year>
<volume>60</volume>
<numero>1-2</numero>
<issue>1-2</issue>
<page-range>101-10</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Montgomery]]></surname>
<given-names><![CDATA[D.C.]]></given-names>
</name>
</person-group>
<source><![CDATA[Design and Analysis of Experiments]]></source>
<year>2012</year>
<edition>8</edition>
<publisher-name><![CDATA[John Wiley &amp; Sons, Ltd.]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>