<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1409-4142</journal-id>
<journal-title><![CDATA[Revista Costarricense de Cardiología]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. costarric. cardiol]]></abbrev-journal-title>
<issn>1409-4142</issn>
<publisher>
<publisher-name><![CDATA[Asociación Costarricense de Cardiología]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1409-41422011000100004</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Marcapasos cardiacos. Estimulación desde el ventrículo derecho: Beneficios y perjuicios a la luz de la experiencia actual]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Garillo]]></surname>
<given-names><![CDATA[Raúl]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Moreno Alvarez]]></surname>
<given-names><![CDATA[Maricruz]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Católica de Argentina Facultad de Medicina ]]></institution>
<addr-line><![CDATA[Buenos Aires ]]></addr-line>
<country>República Argentina</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Hospital de la Mujer  ]]></institution>
<addr-line><![CDATA[Morelia ]]></addr-line>
<country>México</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2011</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2011</year>
</pub-date>
<volume>13</volume>
<numero>1</numero>
<fpage>19</fpage>
<lpage>22</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_arttext&amp;pid=S1409-41422011000100004&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_abstract&amp;pid=S1409-41422011000100004&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_pdf&amp;pid=S1409-41422011000100004&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Se presenta una revisión de la desventaja fisiológica que representa la estimulación apical en el ventrículo derecho. La experiencia clínica ha demostrado además que, en presencia de disfunción contráctil del ventrículo izquierdo, dicha estimulación produce deterioro clínico. Por tal motivo, industria de los marcapasos ha desarrollado modos de estimulación que favorecen la activación miocárdica espontánea o bien, la estimulación permanente biventricular.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Cardiac Pacemakers and Right Ventricle Apical Stimulation: Benefits and Prejudices According to Current Experience A review of the disadvantages of apical right ventricular stimulation is presented. Clinical experience has confirmed that in the presence of left ventricle contractile dysfunction, such a mode of right ventricular stimulation is deleterious. As a result, the pacemaker industry has developed algorithms that promote spontaneous myocardial activation or permanent biventricular stimulation.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[marcapasos]]></kwd>
<kwd lng="es"><![CDATA[estimulación apical]]></kwd>
<kwd lng="es"><![CDATA[resincronización ventricular]]></kwd>
<kwd lng="en"><![CDATA[pacemaker]]></kwd>
<kwd lng="en"><![CDATA[apical stimulation]]></kwd>
<kwd lng="en"><![CDATA[cardiac resinchronisation]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  <b><font face="Verdana" size="4">     <p align="center">Marcapasos cardiacos. Estimulaci&oacute;n desde el ventr&iacute;culo derecho: Beneficios y perjuicios a la luz de la experiencia actual</p> </font></b><font face="Verdana" size="2">     <p style="font-weight: bold;">Ra&uacute;l Garillo<a href="#autor1"><sup>a</sup></a>, Maricruz Moreno Alvarez<a href="#autor2"><sup>b</sup></a></p>     <p><a name="autor1"></a>a. Facultad de Medicina, Universidad Cat&oacute;lica Argentina. Calle Per&uacute; 635, Ciudad Aut&oacute;noma de Buenos Aires (1068), Rep&uacute;blica Argentina. Tel&eacute;fono: +5411 4361 0280 <a href="mailto:raul.aachen@gmail.com">raul.aachen@gmail.com</a>    <br> <a name="autor2"></a>b. Hospital de La Mujer, Morelia, M&eacute;xico.    <br> </p>     <p><a href="#correspondencia">Direcci&oacute;n para correspondencia</a>    <br> </p> </font><b><font face="Verdana" size="3"> </font></b> <hr style="width: 100%; height: 2px;"><b><font face="Verdana" size="3">     <p align="justify">Resumen</p> </font></b>     <p align="justify"><font face="Verdana" size="2">Se presenta una revisi&oacute;n de la desventaja fisiol&oacute;gica que representa la estimulaci&oacute;n apical en el ventr&iacute;culo derecho. La experiencia cl&iacute;nica ha demostrado adem&aacute;s que, en presencia de disfunci&oacute;n contr&aacute;ctil del ventr&iacute;culo izquierdo, dicha estimulaci&oacute;n produce deterioro cl&iacute;nico. Por tal motivo, industria de los marcapasos ha desarrollado modos de estimulaci&oacute;n que favorecen la activaci&oacute;n mioc&aacute;rdica espont&aacute;nea o bien, la estimulaci&oacute;n permanente biventricular.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="Verdana" size="2"><b>Palabras clave:</b> marcapasos &#8211; estimulaci&oacute;n apical &#8211; resincronizaci&oacute;n ventricular.</font></p>     <p align="justify"><b><font face="Verdana" size="3">Abstract</font></b></p>     <p align="justify"><font face="Verdana" size="2">Cardiac Pacemakers and Right Ventricle Apical Stimulation: Benefits and Prejudices According to Current Experience A review of the disadvantages of apical right ventricular stimulation is presented. Clinical experience has confirmed that in the presence of left ventricle contractile dysfunction, such a mode of right ventricular stimulation is deleterious. As a result, the pacemaker industry has developed algorithms that promote spontaneous myocardial activation or permanent biventricular stimulation.</font></p>     <p align="justify"><font face="Verdana" size="2"><b>Key-words:</b> pacemaker &#8211; apical stimulation &#8211; cardiac resinchronisation.</font></p> <hr style="width: 100%; height: 2px;">     <p align="justify"><b><font face="Verdana" size="3">Introducci&oacute;n</font></b></p> <font face="Verdana" size="2">     <p align="justify">Hacia fines de la d&eacute;cada del cincuenta del siglo pasado, comenzaron a implantarse los primeros marcapasos cardiacos. En aquella &eacute;poca, las aspiraciones terap&eacute;uticas eran relativamente modestas: tratar la bradicardia extrema, la crisis de Stokes-Adams y eventualmente, la muerte por falla de la perfusi&oacute;n, esencialmente cerebral. Los a&ntilde;os venideros conocieron notables progresos en el campo tecnol&oacute;gico, tanto en el desarrollo de nuevos materiales y componentes de los electrodos, como en la aplicaci&oacute;n de la nanoingenier&iacute;a para la construcci&oacute;n de marcapasos de menor tama&ntilde;o, mayor duraci&oacute;n, con capacidad para programar m&uacute;ltiples funciones y dotados de una memoria extensa para el almacenamiento de datos cl&iacute;nicos y t&eacute;cnicos. Esto permite un ajuste preciso de su funcionamiento, acorde a las necesidades del paciente y hace m&aacute;s seguro su uso. </p>     <p align="justify">Se pas&oacute; entonces de pensar en accionar del marcapasos seg&uacute;n la cantidad de vida &uacute;til que pod&iacute;a ofrecer, a una visi&oacute;n m&aacute;s completa, en donde a la cantidad de vida se adicionaba la calidad de vida. Grande es el desaf&iacute;o a&uacute;n en el momento actual pues, cualquier sujeto que llega a los 75 a&ntilde;os puede alardear de tener un sistema (su coraz&oacute;n) que le ha prestado un servicio sin interrupciones de algo m&aacute;s de 2.770.000.000 de latidos y bombeado alrededor de 240 millones de litros de sangre hacia todo el organismo. Se comprende f&aacute;cilmente que reemplazar un sistema de semejante eficiencia, a pesar de los extraordinarios avances tecnol&oacute;gicos a los que hemos asistido, constituye una tarea cicl&oacute;pea, por no decir casi imposible. </p> </font><b><font face="Verdana" size="3">     <p align="justify">Cuando la normalidad se transforma en patolog&iacute;a</p> </font></b><font face="Verdana" size="2">     <p align="justify">En las c&aacute;maras ventriculares, donde la masa muscular es significativamente mayor que en los atrios, la corriente de despolarizaci&oacute;n avanza en forma perpendicular a la pared mioc&aacute;rdica, siguiendo la direcci&oacute;n desde endocardio hacia epicardio. El objetivo es evidente: lograr una r&aacute;pida y simult&aacute;nea activaci&oacute;n el&eacute;ctrica de la totalidad de la masa ventricular, y en consecuencia, su contracci&oacute;n mec&aacute;nica sincr&oacute;nica. Los trastornos el&eacute;ctricos intraventriculares alteran este orden de despolarizaci&oacute;n y por ende, el de su desempe&ntilde;o contr&aacute;ctil. El impacto sobre la eficiencia en la funci&oacute;n de bomba y los cambios cl&iacute;nicos que ello puede acarrear son, hasta el presente, motivo de discrepancia entre quienes se han ocupado del tema. En un an&aacute;lisis retrospectivo del estudio "Everest", Wang y cols<sup>1</sup> pudieron establecer un riesgo significativamente mayor en t&eacute;rminos de morbilidad y mortalidad en los sujetos que presentaban un complejo QRS mayor de 120 ms, mas all&aacute; del patr&oacute;n de bloqueo de rama derecha (BRD), bloqueo de rama izquierda (BRI) o trastornos de conducci&oacute;n intraventriculares indefinidos que pudiera exhibir el electrocardiograma. Sin embargo, Padeletti y cols<sup>2</sup> demostraron que, en pacientes con insuficiencia cardiaca, la presencia de BRI constituye un factor independiente de riesgo para mortalidad total y para muerte s&uacute;bita, circunstancia que no pudo comprobarse en cambio en los sujetos que ten&iacute;an BRD. Igual conclusi&oacute;n es sustentada por Olshansky<sup>3</sup>, quien remarca el valor pron&oacute;stico negativo del BRI en t&eacute;rminos de sobrevida en sujetos con insuficiencia cardiaca, mientras que no se demostr&oacute; un efecto semejante cuando la insuficiencia card&iacute;aca se acompa&ntilde;aba de BRD. El BRI como indicador de mal pron&oacute;stico, independiente del grado de suficiencia cardiaca, de la edad del sujeto y del tratamiento que reciba, ha sido se&ntilde;alado por Baldasseroni y cols<sup>4</sup> en una comunicaci&oacute;n reciente. Con referencia a la asincron&iacute;a contr&aacute;ctil inter e intraventricular que los trastornos de conducci&oacute;n promueven, Byrne y cols<sup>5</sup> establecieron con claridad que el BRD perjudica mucho menos la mec&aacute;nica cardiaca que la presencia de BRI.</p>     <p align="justify">Resumiendo lo hasta aqu&iacute; expuesto, escueta fracci&oacute;n de una nutrida bibliograf&iacute;a sobre el tema, puede decirse que el ensanchamiento del complejo QRS encierra connotaciones de gravedad en cuanto a evoluci&oacute;n cl&iacute;nica y pron&oacute;stico de sobrevida, independiente de la etiolog&iacute;a, la edad y otros factores. Y que el patr&oacute;n de BRI es, en la mayor&iacute;a de las comunicaciones, un marcador de mala evoluci&oacute;n; asociado a la presencia de insuficiencia cardiaca, anuncia un pron&oacute;stico sombr&iacute;o, con aumento significativo del riesgo de muerte de cualquier causa, incluida la forma s&uacute;bita.</p> </font><b><font face="Verdana" size="3">     ]]></body>
<body><![CDATA[<p align="justify">Visi&oacute;n actual de la estimulaci&oacute;n cardiaca</p> </font></b><font face="Verdana" size="2">     <p align="justify">Desde inicios de la d&eacute;cada del sesenta, la estimulaci&oacute;n cardiaca ha avanzado desde los marcapasos extremadamente sencillos, voluminosos y con bater&iacute;as de escasa duraci&oacute;n, hasta modelos sofisticados, de peque&ntilde;o tama&ntilde;o y larga duraci&oacute;n, con capacidad para el autocontrol del funcionamiento, para enviar informaci&oacute;n telem&eacute;trica y ofrecer numerosas funciones programables. A un ritmo semejante han evolucionado los electrodos. Sin embargo, un aspecto referido a la t&eacute;cnica de implante se ha mantenido casi invariable en estos &uacute;ltimos cincuenta a&ntilde;os: la colocaci&oacute;n del electrodo ventricular en la punta del ventr&iacute;culo derecho, generando en consecuencia un bloqueo de rama izquierda artificial con cada latido estimulado. El advenimiento de la terapia de resincronizaci&oacute;n cardiaca, el reconocimiento del deterioro contr&aacute;ctil que causa la contracci&oacute;n asincr&oacute;nica y al mismo tiempo, las ventajas de la despolarizaci&oacute;n cardiaca por v&iacute;as naturales, mantiene el debate cient&iacute;fico acerca de la necesidad de ponderar los efectos negativos que la estimulaci&oacute;n desde ventr&iacute;culo derecho y el consiguiente BRI artificial, son capaces de provocar en el coraz&oacute;n.</p>     <p align="justify">El estudio DAVID<sup>6</sup> fue dise&ntilde;ado para comparar sujetos que recib&iacute;an un cardiodesfibrilador implantable (CDI) pero que no requer&iacute;an de la funci&oacute;n de marcapasos. Los pacientes se dividieron en dos grupos: uno programado con estimulaci&oacute;n "de soporte" unicameral (VVI) a 40 latidos por minuto (lpm) y el otro, programado en modo de estimulaci&oacute;n bicameral (DDDR) a 70 lpm. Los puntos finales eran hospitalizaci&oacute;n por insuficiencia cardiaca, mortalidad de toda causa y la combinaci&oacute;n de ambos. El resultado fue que el punto final combinado (hospitalizaci&oacute;n por insuficiencia cardiaca o muerte de cualquier causa) fue significativamente mayor en el grupo con estimulaci&oacute;n del modo DDDR &#8211; 70 lpm. Los investigadores plantearon que este resultado desfavorable en modo DDDR-70 pod&iacute;a atribuirse a 3 causas diferentes: a) activaci&oacute;n anormal desde ventr&iacute;culo derecho (VD), generando un BRI artificial, b) una frecuencia impuesta demasiado alta (70 lpm), para individuos que ya ten&iacute;an un deterioro de la funci&oacute;n ventricular y c) una programaci&oacute;n del intervalo atrioventricular (AV) muy corto, lo cual sobrepasa al tiempo de conducci&oacute;n fisiol&oacute;gica a trav&eacute;s del nodo AV y genera alteraciones hemodin&aacute;micas; en particular en la secuencia contr&aacute;ctil mec&aacute;nica atrial y ventricular izquierda, impuesta por la estimulaci&oacute;n artificial desde VD, que el paciente no requer&iacute;a.</p>     <p align="justify">En el estudio DAVID II<sup>7</sup>, con un protocolo similar al DAVID, se modific&oacute; &uacute;nicamente el modo de estimulaci&oacute;n: se reemplaz&oacute; el modo DDDR por modo unicameral en atrio derecho (AAI-70). Los resultados, comparados con el modo de estimulaci&oacute;n VVI-40 fueron semejantes, excluyendo de este modo la hip&oacute;tesis (b) de la alta frecuencia y acentuando la responsabilidad de la estimulaci&oacute;n desde el &aacute;pex del VD en los efectos delet&eacute;reos obtenidos originalmente en el primer estudio DAVID. Con respecto a la tercera hip&oacute;tesis (c), referida al intervalo AV artificialmente corto, el grupo de Sharma y cols<sup>8</sup> revis&oacute; los resultados del estudio DAVID y encontr&oacute; 3 subgrupos (<a href="#fig1">Fig. 1</a>). De manera indiscutible, los sujetos que acumularon el mayor tiempo de estimulaci&oacute;n presentaron el porcentaje mayor de trastornos hemodin&aacute;micas, incluyendo el empeoramiento de la insuficiencia cardiaca; los que solo recibieron estimulaci&oacute;n de soporte (VVI-40 ppm) tuvieron el menor porcentaje de estimulaci&oacute;n al d&iacute;a (4%) y aquellos programados en modo DDDR pero con intervalo AV largo, acumularon solamente 11% de estimulaci&oacute;n diaria. Contra lo esperado, los pacientes con mejor tolerancia a la estimulaci&oacute;n artificial fueron hallados en el tercer grupo, lo que se&ntilde;al&oacute; dos conclusiones de valor cl&iacute;nico: la mejor situaci&oacute;n es no estimular innecesariamente; pero si debe hacerse, es preferible respetar la secuencia AV, siempre y cuando no se acumule un porcentaje de estimulaci&oacute;n muy alto. De lo antedicho se desprende que en el modo VVI-40 lpm de soporte, aunque el porcentaje de estimulaci&oacute;n sea bajo, la ausencia de secuencia AV y la posible conducci&oacute;n retr&oacute;grada, implican desventajas que deben ser tenidas en cuenta al momento de calcular beneficios para el paciente.    <br> </p>     <p align="justify">    <br> </p>     <p align="justify">    <br> </p> </font>     <div style="text-align: center;"><a name="fig1"></a><img  src="/img/revistas/rcc/v13n1/a04i1.jpg" title="" alt=""  style="width: 431px; height: 360px;">    ]]></body>
<body><![CDATA[<br>     <br> </div> <font face="Verdana" size="2">     <p align="justify"> </p> </font><b><font face="Verdana" size="3">     <p align="justify">Cuando es el porcentaje quien decide</p> </font></b><font face="Verdana" size="2">     <p align="justify">La estimulaci&oacute;n desde &aacute;pex del VD genera cambios fisiol&oacute;gicos agudos y cr&oacute;nicos. Los efectos agudos est&aacute;n dominados por el cambio en la secuencia de activaci&oacute;n ventricular, remodelado el&eacute;ctrico e inmediato deterioro de la funci&oacute;n ventricular, como lo demostraran Nahlawi y col<sup>9</sup>. Los cambios cr&oacute;nicos incluyen modificaciones en el tono auton&oacute;mico, remodelado anat&oacute;mico de los ventr&iacute;culos y alteraciones en los canales i&oacute;nicos, una de cuyas expresiones es la variaci&oacute;n del frente de repolarizaci&oacute;n ventricular, que puede persistir a&uacute;n cuando haya cesado la estimulaci&oacute;n (memoria electrot&oacute;nica, <a href="#fig2">Fig. 2</a>)<sup>10</sup>. Estas modificaciones adquieren mayor preponderancia en funci&oacute;n del porcentaje de estimulaci&oacute;n ventricular acumulado en el tiempo. Tanto en la serie de Sweeney<sup>11</sup> como en la de Sharma8, los trastornos hemodin&aacute;micos y el empeoramiento o aparici&oacute;n de la insuficiencia cardiaca fueron observados a partir del 40% del tiempo diario acumulado de estimulaci&oacute;n ventricular. Un subestudio del MADIT II aport&oacute; tambi&eacute;n resultados congruentes con los ya descriptos, aunque por el modelo de an&aacute;lisis empleado, el punto de inflexi&oacute;n de la curva de complicaciones se obtuvo a partir del 50% del tiempo diario acumulado de estimulaci&oacute;n<sup>12</sup>.    <br> </p>     <p align="justify">    <br> </p>     <p align="justify">    <br> </p> </font>     ]]></body>
<body><![CDATA[<div style="text-align: center;"><font face="Verdana" size="2">     <p align="justify"></p> </font>     <div style="text-align: center;"><a name="fig2"></a><img  src="/img/revistas/rcc/v13n1/a04i2.jpg" title="" alt=""  style="width: 444px; height: 314px;">    <br> </div>     <br> <font face="Verdana" size="2">     <p align="justify"> </p> </font></div> <font face="Verdana" size="2"></font>     <p align="justify"><b><font face="Verdana" size="3">Bajo el imperio del </font><i><font size="3">"</font><font face="Verdana" size="3">Primum Non Nocere"</font></i></b></p> <font face="Verdana" size="2">     <p align="justify">La medicina preventiva procura evitar complicaciones atribuibles a cualquier tratamiento instaurado. En las gu&iacute;as internacionales<sup>13</sup> para el implante de dispositivos de estimulaci&oacute;n cardiaca publicadas durante 2010, se contempla que para los pacientes con indicaci&oacute;n Clase I de implante de marcapasos y adem&aacute;s con diversos grados de insuficiencia cardiaca y fracci&oacute;n de eyecci&oacute;n baja, se utilice terapia de resincronizaci&oacute;n cardiaca, independientemente de la duraci&oacute;n del complejo QRS nativo, ya que asumen que un dispositivo convencional que estimule el VD empeorar&aacute; la condici&oacute;n cl&iacute;nica del paciente (cuadro I). Sin embargo, m&aacute;s all&aacute; de la bibliograf&iacute;a reciente, que nos alerta con relaci&oacute;n a los efectos negativos que engendra la estimulaci&oacute;n desde la punta del VD<sup>14,15</sup>, existe entre los expertos una fuerte corriente de opini&oacute;n que sostiene la inocuidad de esa forma de estimulaci&oacute;n, apoyados en la enorme cantidad de pacientes implantados a lo largo de 50 a&ntilde;os y en el bajo &iacute;ndice de complicaciones atribuibles a esa t&eacute;cnica. </p>     <p align="justify">La b&uacute;squeda de una respuesta satisfactoria sobre el potencial da&ntilde;o que genera la estimulaci&oacute;n desde el &aacute;pex del VD debe partir del an&aacute;lisis del propio BRI. Anat&oacute;micamente, la distribuci&oacute;n del haz de His y sus ramas en los mam&iacute;feros superiores es el resultado evolutivo, desde la aparici&oacute;n de esta estructura en los miembros m&aacute;s antiguos de esta clase, a una forma perfectamente adaptada a la mec&aacute;nica de cada ventr&iacute;culo. La rama derecha es de mayor grosor y se ramifica reci&eacute;n al llegar al pie del m&uacute;sculo papilar anterior; en cambio, la rama izquierda se divide y arboriza r&aacute;pidamente, dando ramas de menor calibre que se extienden como una malla. De esa forma, se garantiza la eficiencia mec&aacute;nica del ventr&iacute;culo izquierdo, un sistema de alta presi&oacute;n y de alta tensi&oacute;n (ley de Laplace) que impone condiciones duras al sistema el&eacute;ctrico mioc&aacute;rdico. Por tanto, la presencia de BRI sugiere casi siempre un da&ntilde;o extenso y difuso de la cavidad ventricular izquierda, con el previsible compromiso de su funci&oacute;n contr&aacute;ctil. Aunque la estimulaci&oacute;n artificial desde el &aacute;pex del VD origine el&eacute;ctricamente tambi&eacute;n un BRI, no necesariamente implica compromiso funcional severo del VI como s&iacute; ocurre con el BRI espont&aacute;neo. De manera que, solamente los individuos con deterioro previo de la funci&oacute;n contr&aacute;ctil ventricular que reciben marcapasos desarrollar&aacute;n complicaciones atribuibles a la estimulaci&oacute;n artificial, con un abanico de posibilidades en directa relaci&oacute;n a la cuant&iacute;a del compromiso ventricular y del porcentaje de estimulaci&oacute;n a que se vea sometido. </p> </font><b><font face="Verdana" size="3">     <p align="justify">El electrodo en el apex del ventr&iacute;culo derecho, sus or&iacute;genes</p> </font></b><font face="Verdana" size="2">     ]]></body>
<body><![CDATA[<p align="justify">El posicionamiento del electrodo en el apex del VD obedeci&oacute; en sus inicios a las limitaciones t&eacute;cnicas de los electrodos, tanto para soportar el estr&eacute;s mec&aacute;nico de la contracci&oacute;n continua, como para mantenerse confiablemente en una ubicaci&oacute;n determinada. El extraordinario avance tecnol&oacute;gico de las &uacute;ltimas d&eacute;cadas ha transformado radicalmente esa situaci&oacute;n y los electrodos contempor&aacute;neos son capaces de tolerar el trauma de la contracci&oacute;n cardiaca por muchos a&ntilde;os, contando adem&aacute;s con sistemas de fijaci&oacute;n confiables, que permiten colocar el electrodo pr&aacute;cticamente en cualquier zona del ventr&iacute;culo que se pretenda. Es as&iacute; que en la actualidad, muchos implantadores optan por colocar el electrodo sobre el tabique interventricular, a nivel del tracto de salida del VD<sup>16-19</sup>. Las ventajas de este abordaje ser&iacute;an la obtenci&oacute;n de un complejo QRS relativamente angosto y una despolarizaci&oacute;n desde la base hacia el apex del ventr&iacute;culo, determinando complejos QRS positivos en las derivaciones inferiores II, III y aVF, semejantes en su polaridad a los observados en el electrocardiograma normal. M&uacute;ltiples comunicaciones empleando electrodos de fijaci&oacute;n activa, han dado cuenta de la factibilidad y confiabilidad de emplear esta t&eacute;cnica; sin embargo hasta la fecha, salvo escasas excepciones<sup>20</sup>, pr&aacute;cticamente no existen estudios bien dise&ntilde;ados que demuestren de manera s&oacute;lida sus beneficios en t&eacute;rminos de morbilidad y mortalidad, por lo que su adopci&oacute;n de manera generalizada depender&aacute; de futuras investigaciones al respecto.</p> </font><b><font face="Verdana" size="3">     <p align="justify">Otras reflexiones</p> </font></b><font face="Verdana" size="2">     <p align="justify">En definitiva, quienes hoy se dediquen como especialistas a la estimulaci&oacute;n cardiaca, deben adoptar y difundir entre el resto de sus colegas una nueva forma de encarar la terapia el&eacute;ctrica del coraz&oacute;n, con el uso de la tecnolog&iacute;a recientemente desarrollada en este campo, entre cuyos objetivos se destaca claramente la estimulaci&oacute;n septal, la sincronizaci&oacute;n y la promoci&oacute;n del ritmo natural por sobre toda otra circunstancia, dejando a los sistemas de estimulaci&oacute;n la tarea de actuar cuando no exista ninguna otra alternativa. En este punto, las distintas empresas fabricantes de marcapasos han desarrollado sistemas<sup>21</sup> y a&uacute;n, modos de estimulaci&oacute;n<sup>22</sup> (<a href="/img/revistas/rcc/v13n1/a04i3.jpg">Fig. 3</a>), que promueven el ritmo espont&aacute;neo del paciente a ultranza. Los marcapasos adem&aacute;s proveen una voluminosa informaci&oacute;n que se almacena en la memoria, tal como los porcentajes de tiempo bajo estimulaci&oacute;n, ritmos anormales, extras&iacute;stoles, etc. Esa informaci&oacute;n permite ajustes de programaci&oacute;n, instauraci&oacute;n o modificaciones de la terapia farmacol&oacute;gica y a&uacute;n conductas mas decisivas como la ablaci&oacute;n por cat&eacute;ter o el implante de sistemas de mayor complejidad como cardiodesfibriladores y sincronizadores card&iacute;acos<sup>23</sup>. Obvia decir que en este universo tecnol&oacute;gico complejo y caro, pero de mayor beneficio para el paciente en su calidad y cantidad de vida, los primitivos sistemas de estimulaci&oacute;n ventricular unicamerales (VVI), han entrado definitivamente en la obsolescencia.</p> </font><b><font face="Verdana" size="3"> </font></b> <hr style="width: 100%; height: 2px;"><b><font face="Verdana" size="3">     <p align="justify">Referencias</p> </font></b><font face="Verdana" size="2">     <!-- ref --><p align="justify">1. Wang NC, Maggioni AP, Konstam MA et al. Clinical implications of QRS duration in patients hospitalized with worsening heart failure and reduced left ventricular ejection fraction. JAMA 2008; 299: 2656-2666.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754086&pid=S1409-4142201100010000400001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p align="justify">2. Padeletti L, Valleggi A, Vergaro G et al. Concordant versus discordant left bundle branch block in heart failure: novel clinical value of an old electrocardiographic diagnosis. J Card Fail 2010; 16: 320-326.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754088&pid=S1409-4142201100010000400002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p align="justify">3. Olshansky B. Wide QRS, narrow QRS. What&#8217;s the difference? J Am Coll Cardiol 2005; 46: 317-319.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754090&pid=S1409-4142201100010000400003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify">4. Baldasseroni S, Opasich C, Gorini M et al. Left bundle branch blockis associated with increase 1-year sudden and total mortality rate in 5517 outpatients with congestive heart failure: a report from the Italian network of congestive heart failure. Am Heart J 2002; 143: 398-405.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754092&pid=S1409-4142201100010000400004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p align="justify">5. Byrne MJ, Helm RH, Samantapudi D et al. Diminished left ventricular dyssynchrony and impact of resynchronization in failing hearts with right versus left bundle branch block. J Am Coll Cardiol 2007; 50: 1484-1490.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754094&pid=S1409-4142201100010000400005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p align="justify">6. DAVID trial investigators. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator. JAMA 2002; 288: 3115-3123.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754096&pid=S1409-4142201100010000400006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p align="justify">7. Wilkoff BL, Kudenchuck PJ, Buxton AE et al. The DAVID (Dual chamber and VVI implantable defibrillator) II trial. J Am Coll Cardiol 2009; 53: 872-880.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754098&pid=S1409-4142201100010000400007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p align="justify">8. Sharma AD, Rizzo-Patron C, Hallstrom AP et al. Percent right ventricular pacing predicts outcomes in the DAVID trial. Heart Rhythm 2005; 2: 830-834.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754100&pid=S1409-4142201100010000400008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify">9. Nahlawi M, Waligora M, Spies SM et al. Left ventricular function during and after right ventricular pacing. J Am Coll Cardiol 2004; 44: 1883-1888.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754102&pid=S1409-4142201100010000400009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p align="justify">10. Rosenbaum MB, Blanco HM, Elizari MV et al. Electrotonic modulation of the T wave and cardiac memory. Am J Cardiol 1982; 50: 213-219.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754104&pid=S1409-4142201100010000400010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p align="justify">11. Sweeney MO, Hellkamp AS, Ellenbogen KA et al. Adverse effect of ventricular acing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation 2003; 107: 2932-2937.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754106&pid=S1409-4142201100010000400011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p align="justify">12. Steinberg JS, Fisher A, Wang P et al. The clinical implications cumulative of right ventricular pacing in The Multicenter Automatic Defibrillator Trial II. J Cardiovasc Electrophysiol 2005; 16: 359-365.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754108&pid=S1409-4142201100010000400012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p align="justify">13. European Heart Journal Guidelines. Sitio Web: www.eurheartj.oxford.org (advance access published august 27, 2010).    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754110&pid=S1409-4142201100010000400013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify">14. Ellenbogen KA, Wood MA. Pacemaker selection &#8211; The chamging definition of physiologic pacing. N Engl J Med 2005; 353: 202-204.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754112&pid=S1409-4142201100010000400014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p align="justify">15. Kindermann M, Hennen B, Jung J et al. Biventricular versis conventional right ventricular stimulation for patients with standard pacing indication and left ventricular dysfunction. J Am Coll Cardiol 2006; 47: 1927-1937.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754114&pid=S1409-4142201100010000400015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p align="justify">16. Medi C, Mond HG. Right ventricular outflow tract pacing: long term follow- up of ventricular performance. Pacing Clin Electrophysiol 2009; 32: 172-176.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754116&pid=S1409-4142201100010000400016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p align="justify">17. Hillock RJ, Stevenson IH, Mond HG. The right ventricular outflow tract: A comparative study of septal, anterior wall, free wall pacing. Pacing Clin Electrophysiol 2007; 30: 942-947.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754118&pid=S1409-4142201100010000400017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p align="justify">18. McGavigan AD, Roberts-Thompson KC, Hillock RJ et al. Right ventricular outflow tract pacing: radiographic and electrocardiographic correlates of lead position. Pacing Clin Electrophysiol 2006; 29: 1063-1068.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754120&pid=S1409-4142201100010000400018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify">19. Francis J, Jayesh B, Ashishkumar M et al. Right ventricular septal pacing: has it come of age?. Indian Pacing Electrophysiol J 2010; 10: 69-72.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754122&pid=S1409-4142201100010000400019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p align="justify">20. Vanerio G, Vidal JL, Banizi PF et al. Medium and long-term survival after pacemaker implant: improved survival with right ventricular outflow tract pacing. J Interv Card Electrophysiol 2008; 21: 195-201.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754124&pid=S1409-4142201100010000400020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p align="justify">21. Olshansky B, Day J, Moore S et al. Is dual chamber programming inferior to single-chamber programming in an implantable cardioverter-defibrillator? Circulation 2007; 115: 9-16.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754126&pid=S1409-4142201100010000400021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p align="justify">22. Sweeney MO, Ellebogen KA, Casavant D et al. Multicenter prospective randomized safety and efficacy study of a new atrial-based managed ventricular pacing mode (MVP) in dual chamber ICDs. J Cardiovasc Electrophysiol 2005; 16: 811-817.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754128&pid=S1409-4142201100010000400022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p align="justify">23. Garillo R. Muerte s&uacute;bita cardiaca: las 7 preguntas para las cuales todo cardi&oacute;logo debe de tener respuesta. Arch Cardiol Mex 2010; 80: 199-204.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=754130&pid=S1409-4142201100010000400023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><br> </p>     ]]></body>
<body><![CDATA[<p align="justify">    <br> </p>     <p align="justify"><a name="correspondencia"></a>Correspondencia a: <font  face="Verdana" size="2">Ra&uacute;l Garillo. </font><font><font face="Verdana" size="2">Facultad de Medicina, Universidad Cat&oacute;lica Argentina. Calle Per&uacute; 635, Ciudad Aut&oacute;noma de Buenos Aires (1068), Rep&uacute;blica Argentina. Tel&eacute;fono: +5411 4361 0280 <a href="mailto:raul.aachen@gmail.com">raul.aachen@gmail.com</a>    <br> </font></font><font face="Verdana" size="2">Maricruz Moreno Alvarez. </font><font><font  face="Verdana" size="2">Hospital de La Mujer, Morelia, M&eacute;xico</font></font></p> </font>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[NC]]></given-names>
</name>
<name>
<surname><![CDATA[Maggioni]]></surname>
<given-names><![CDATA[AP]]></given-names>
</name>
<name>
<surname><![CDATA[Konstam]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinical implications of QRS duration in patients hospitalized with worsening heart failure and reduced left ventricular ejection fraction]]></article-title>
<source><![CDATA[JAMA]]></source>
<year>2008</year>
<volume>299</volume>
<page-range>2656-2666</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Padeletti]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Valleggi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Vergaro]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Concordant versus discordant left bundle branch block in heart failure: novel clinical value of an old electrocardiographic diagnosis]]></article-title>
<source><![CDATA[J Card Fail]]></source>
<year>2010</year>
<volume>16</volume>
<page-range>320-326</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Olshansky]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Wide QRS, narrow QRS: What’s the difference]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2005</year>
<volume>46</volume>
<page-range>317-319</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Baldasseroni]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Opasich]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Gorini]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Left bundle branch blockis associated with increase 1-year sudden and total mortality rate in 5517 outpatients with congestive heart failure: a report from the Italian network of congestive heart failure]]></article-title>
<source><![CDATA[Am Heart J]]></source>
<year>2002</year>
<volume>143</volume>
<page-range>398-405</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Byrne]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Helm]]></surname>
<given-names><![CDATA[RH]]></given-names>
</name>
<name>
<surname><![CDATA[Samantapudi]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Diminished left ventricular dyssynchrony and impact of resynchronization in failing hearts with right versus left bundle branch block]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2007</year>
<volume>50</volume>
<page-range>1484-1490</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<collab>DAVID trial investigators</collab>
<article-title xml:lang="en"><![CDATA[Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator]]></article-title>
<source><![CDATA[JAMA]]></source>
<year>2002</year>
<volume>288</volume>
<page-range>3115-3123</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wilkoff]]></surname>
<given-names><![CDATA[BL]]></given-names>
</name>
<name>
<surname><![CDATA[Kudenchuck]]></surname>
<given-names><![CDATA[PJ]]></given-names>
</name>
<name>
<surname><![CDATA[Buxton]]></surname>
<given-names><![CDATA[AE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The DAVID (Dual chamber and VVI implantable defibrillator) II trial]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2009</year>
<volume>53</volume>
<page-range>872-880</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sharma]]></surname>
<given-names><![CDATA[AD]]></given-names>
</name>
<name>
<surname><![CDATA[Rizzo-Patron]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Hallstrom]]></surname>
<given-names><![CDATA[AP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Percent right ventricular pacing predicts outcomes in the DAVID trial]]></article-title>
<source><![CDATA[Heart Rhythm]]></source>
<year>2005</year>
<volume>2</volume>
<page-range>830-834</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nahlawi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Waligora]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Spies]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Left ventricular function during and after right ventricular pacing]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2004</year>
<volume>44</volume>
<page-range>1883-1888</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosenbaum]]></surname>
<given-names><![CDATA[MB]]></given-names>
</name>
<name>
<surname><![CDATA[Blanco]]></surname>
<given-names><![CDATA[HM]]></given-names>
</name>
<name>
<surname><![CDATA[Elizari]]></surname>
<given-names><![CDATA[MV]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrotonic modulation of the T wave and cardiac memory]]></article-title>
<source><![CDATA[Am J Cardiol]]></source>
<year>1982</year>
<volume>50</volume>
<page-range>213-219</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sweeney]]></surname>
<given-names><![CDATA[MO]]></given-names>
</name>
<name>
<surname><![CDATA[Hellkamp]]></surname>
<given-names><![CDATA[AS]]></given-names>
</name>
<name>
<surname><![CDATA[Ellenbogen]]></surname>
<given-names><![CDATA[KA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Adverse effect of ventricular acing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2003</year>
<volume>107</volume>
<page-range>2932-2937</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Steinberg]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
<name>
<surname><![CDATA[Fisher]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The clinical implications cumulative of right ventricular pacing in The Multicenter Automatic Defibrillator Trial II]]></article-title>
<source><![CDATA[J Cardiovasc Electrophysiol]]></source>
<year>2005</year>
<volume>16</volume>
<page-range>359-365</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="">
<source><![CDATA[European Heart Journal Guidelines]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ellenbogen]]></surname>
<given-names><![CDATA[KA]]></given-names>
</name>
<name>
<surname><![CDATA[Wood]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Pacemaker selection - The chamging definition of physiologic pacing]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>2005</year>
<volume>353</volume>
<page-range>202-204</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kindermann]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Hennen]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Jung]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biventricular versis conventional right ventricular stimulation for patients with standard pacing indication and left ventricular dysfunction]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2006</year>
<volume>47</volume>
<page-range>1927-1937</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Medi]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Mond]]></surname>
<given-names><![CDATA[HG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Right ventricular outflow tract pacing: long term follow- up of ventricular performance]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2009</year>
<volume>32</volume>
<page-range>172-176</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hillock]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
<name>
<surname><![CDATA[Stevenson]]></surname>
<given-names><![CDATA[IH]]></given-names>
</name>
<name>
<surname><![CDATA[Mond]]></surname>
<given-names><![CDATA[HG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The right ventricular outflow tract: A comparative study of septal, anterior wall, free wall pacing]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2007</year>
<volume>30</volume>
<page-range>942-947</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McGavigan]]></surname>
<given-names><![CDATA[AD]]></given-names>
</name>
<name>
<surname><![CDATA[Roberts-Thompson]]></surname>
<given-names><![CDATA[KC]]></given-names>
</name>
<name>
<surname><![CDATA[Hillock]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Right ventricular outflow tract pacing: radiographic and electrocardiographic correlates of lead position]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2006</year>
<volume>29</volume>
<page-range>1063-1068</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Francis]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Jayesh]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Ashishkumar]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Right ventricular septal pacing: has it come of age]]></article-title>
<source><![CDATA[Indian Pacing Electrophysiol J]]></source>
<year>2010</year>
<volume>10</volume>
<page-range>69-72</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vanerio]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Vidal]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Banizi]]></surname>
<given-names><![CDATA[PF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Medium and long-term survival after pacemaker implant: improved survival with right ventricular outflow tract pacing]]></article-title>
<source><![CDATA[J Interv Card Electrophysiol]]></source>
<year>2008</year>
<volume>21</volume>
<page-range>195-201</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Olshansky]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Day]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Moore]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Is dual chamber programming inferior to single-chamber programming in an implantable cardioverter-defibrillator]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2007</year>
<volume>115</volume>
<page-range>9-16</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sweeney]]></surname>
<given-names><![CDATA[MO]]></given-names>
</name>
<name>
<surname><![CDATA[Ellebogen]]></surname>
<given-names><![CDATA[KA]]></given-names>
</name>
<name>
<surname><![CDATA[Casavant]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Multicenter prospective randomized safety and efficacy study of a new atrial-based managed ventricular pacing mode (MVP) in dual chamber ICDs]]></article-title>
<source><![CDATA[J Cardiovasc Electrophysiol]]></source>
<year>2005</year>
<volume>16</volume>
<page-range>811-817</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Garillo]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Muerte súbita cardiaca: las 7 preguntas para las cuales todo cardiólogo debe de tener respuesta]]></article-title>
<source><![CDATA[Arch Cardiol Mex]]></source>
<year>2010</year>
<volume>80</volume>
<page-range>199-204</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
