<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1409-4142</journal-id>
<journal-title><![CDATA[Revista Costarricense de Cardiología]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. costarric. cardiol]]></abbrev-journal-title>
<issn>1409-4142</issn>
<publisher>
<publisher-name><![CDATA[Asociación Costarricense de Cardiología]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1409-41422004000300003</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Prevalencia de terapias inadecuadas con cardiodesfibriladores en la Clínica de Arritmias del Hospital México]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Gutiérrez Sotelo]]></surname>
<given-names><![CDATA[Oswaldo]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Caja Costarricense de Seguro Social Hospital México ]]></institution>
<addr-line><![CDATA[San José ]]></addr-line>
<country>Costa Rica</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>09</month>
<year>2004</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>09</month>
<year>2004</year>
</pub-date>
<volume>6</volume>
<numero>3</numero>
<fpage>7</fpage>
<lpage>12</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_arttext&amp;pid=S1409-41422004000300003&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_abstract&amp;pid=S1409-41422004000300003&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_pdf&amp;pid=S1409-41422004000300003&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Introducción: Los cardiodesfibriladores implantables están indicados en los pacientes que han tenido paro cardiorrespiratorio y/o taquicardia ventricular/fibrilación ventricular. Las terapias que administran son estimulación antitaquicardia, cardioversión y desfibrilación y existen diversos métodos matemáticos mediante los cuales estos dispositivos pueden discriminar si una taquiarritmia es ventricular o supraventricular. Cuando hay errores en la discriminación, administran terapias en forma inadecuada con consecuencias negativas en la calidad de vida y la vida útil de la batería. Metodología: El objetivo de este estudio es conocer la prevalencia de terapias inadecuadas en los pacientes portadores de cardiodesfibriladores implantables que se han controlado en la clínica de arritmias de nuestro centro en el período junio-2002 a julio-2004. Se interrogó por telemetría a todos los pacientes y se estableció si la terapia administrada por el dispositivo era adecuada en base a los electrogramas almacenados. Resultados: Se registraron 99 eventos almacenados en 16 pacientes. El número total de visitas a la clínica de marcapasos fue 33 (2.05 visitas/paciente). De los 99 eventos registrados, se consideró 22 como inadecuados (22.22%); si se excluye del análisis a un paciente con displasia arritmogénica del ventrículo derecho que tuvo 64 eventos adecuados el mismo día y otro con 17 cardioversiones el mismo día debidas a fibrilación atrial aguda, se obtiene una prevalencia de terapias inadecuadas del 45.45%. Conclusión: La prevalencia de terapias inadecuadas es relativamente frecuente y la más común en esta serie fue la fibrilación atrial interpretada como fibrilación ventricular debidas a errores en la discriminación.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Introduction: Implantable cardiodesfibrillators are indicated in patients with history of cardiorespiratory arrest and/or ventricular tachycardia/ventricular fibrillation. Therapies delivered by these devices includes antitachycardia pacing, cardioversion and defibrillation and there are mathematical algorithms to discriminate if an arrhythmia diagnosed is of ventricular or supraventricular origin. Because of mistakes during interpretation these devices can deliver inadequate therapies with negative consequences in quality of life and battery’s lifespan. Methods: The main objective of this study is to evaluate prevalence of inadequate therapies in patients with implanted defibrillators who were follow-up in the arrhythmia department of our hospital since june-2002 to july-2004. All devices were interrogated by telemetry and arrhythmic events were evaluated by mean of stored electrograms, assessing if delivered therapy was adequate or not. Results: There were 99 arrhythmic events stored in 16 patients. The total number of visits to the arrhythmia department were 33 (2.05 visits/patient). From 99 stored events, 22 were considered as inadequate (22.22%); excluding one patient with arrhythmogenic right ventricular dysplasia who had 64 adequately treated episodes on the same day and another one with 17 cardioversions the same day due to acute atrial fibrillation, prevalence of inadequate therapies was 45.45%. Conclusion: Prevalence of inadequate therapies is relatively frequent and the most common in this serie is atrial fibrillation interpreted as ventricular fibrillation due to misdiagnosis.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Cardiodesfibriladores]]></kwd>
<kwd lng="es"><![CDATA[Terapias Inadecuadas]]></kwd>
<kwd lng="en"><![CDATA[Cardiodesfibrillators]]></kwd>
<kwd lng="en"><![CDATA[Inadecuate Therapies]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <div style="text-align: center;"><span  style="font-family: arial; font-weight: bold;">Prevalencia de terapias inadecuadas con     <br> cardiodesfibriladores en la Clínica </span><span  style="font-family: arial; font-weight: bold;">de </span>    <br> <span style="font-family: arial; font-weight: bold;">Arritmias</span> <span  style="font-family: arial; font-weight: bold;">del Hospital México.</span>    <br> </div> <b><font face="Arial"></font></b>     <div style="text-align: right;"><font face="Arial" size="2">    <br> <a href="#a02">*</a> Dr. Oswaldo Gutiérrez Sotelo</font></div>     <p><b><font face="Arial" size="2">Resumen </font></b></p> <font face="Arial" size="2"><u></u></font>     <p><font face="Arial" size="2"><u>Introducción</u>: Los cardiodesfibriladores implantables están indicados en los pacientes que han tenido paro cardiorrespiratorio y/o taquicardia ventricular/fibrilación ventricular. Las terapias que administran son estimulación antitaquicardia, cardioversión y desfibrilación y existen diversos métodos matemáticos mediante los cuales estos dispositivos pueden discriminar si una taquiarritmia es ventricular o supraventricular. Cuando hay errores en la discriminación, administran terapias en forma inadecuada con consecuencias negativas en la calidad de vida y la vida útil de la batería. </font></p> <font face="Arial" size="2"><u></u></font>     <p><font face="Arial" size="2"><u>Metodología</u>: El objetivo de este estudio es conocer la prevalencia de terapias inadecuadas en los pacientes portadores de cardiodesfibriladores implantables que se han controlado en la clínica de arritmias de nuestro centro en el período junio-2002 a julio-2004. Se interrogó por telemetría a todos los pacientes y se estableció si la terapia administrada por el dispositivo era adecuada en base a los electrogramas almacenados. </font></p> <font face="Arial" size="2"><u></u></font>     <p><font face="Arial" size="2"><u>Resultados</u>: Se registraron 99 eventos almacenados en 16 pacientes. El número total de visitas a la clínica de marcapasos fue 33 (2.05 visitas/paciente). De los 99 eventos registrados, se consideró 22 como inadecuados (22.22%); si se excluye del análisis a un paciente con displasia arritmogénica del ventrículo derecho que tuvo 64 eventos adecuados el mismo día y otro con 17 cardioversiones el mismo día debidas a fibrilación atrial aguda, se obtiene una prevalencia de terapias inadecuadas del 45.45%. </font></p> <font face="Arial" size="2"><u></u></font>     ]]></body>
<body><![CDATA[<p><font face="Arial" size="2"><u>Conclusión</u>: La prevalencia de terapias inadecuadas es relativamente frecuente y la más común en esta serie fue la fibrilación atrial interpretada como fibrilación ventricular debidas a errores en la discriminación.</font></p> <font face="Arial" size="2"><u></u></font>     <p><font face="Arial" size="2"><u>Palabras Clave</u>: Cardiodesfibriladores. Terapias Inadecuadas. </font></p>     <p><font face="Arial" size="2">&nbsp;</font></p> <font face="Arial" size="2"><b>     <p>Abstract </p> </b> <u></u></font>     <p><font face="Arial" size="2"><u>Introduction</u>: Implantable cardiodesfibrillators are indicated in patients with history of cardiorespiratory arrest and/or ventricular tachycardia/ventricular fibrillation. Therapies delivered by these devices includes antitachycardia pacing, cardioversion and defibrillation and there are mathematical algorithms to discriminate if an arrhythmia diagnosed is of ventricular or supraventricular origin. Because of mistakes during interpretation these devices can deliver inadequate therapies with negative consequences in quality of life and battery’s lifespan. </font></p> <font face="Arial" size="2"><u></u></font>     <p><font face="Arial" size="2"><u>Methods</u>: The main objective of this study is to evaluate prevalence of inadequate therapies in patients with implanted defibrillators who were follow-up in the arrhythmia department of our hospital since june-2002 to july-2004. All devices were interrogated by telemetry and arrhythmic events were evaluated by mean of stored electrograms, assessing if delivered therapy was adequate or not. </font></p> <font face="Arial" size="2"><u></u></font>     <p><font face="Arial" size="2"><u>Results</u>: There were 99 arrhythmic events stored in 16 patients. The total number of visits to the arrhythmia department were 33 (2.05 visits/patient). From 99 stored events, 22 were considered as inadequate (22.22%); excluding one patient with arrhythmogenic right ventricular dysplasia who had 64 adequately treated episodes on the same day and another one with 17 cardioversions the same day due to acute atrial fibrillation, prevalence of inadequate therapies was 45.45%. </font></p> <font face="Arial" size="2"><u></u></font>     <p><font face="Arial" size="2"><u>Conclusion</u>: Prevalence of inadequate therapies is relatively frequent and the most common in this serie is atrial fibrillation interpreted as ventricular fibrillation due to misdiagnosis. </font></p> <font face="Arial" size="2"><u></u></font>     <p><font face="Arial" size="2"><u>Keywords</u>: Cardiodesfibrillators. Inadecuate Therapies. </font></p>     <p><font face="Arial" size="2">&nbsp;</font></p> <font face="Arial" size="2"><b>     ]]></body>
<body><![CDATA[<p>Introducción</p> </b> </font>     <p><font face="Arial" size="2">En la última década se ha acumulado abundante evidencia científica que demuestra el beneficio de la terapia con cardiodesfibriladores implantables. Hay consenso <a href="#1"><sup>1</sup></a> en cuanto a su indicación en pacientes que han presentado taquicardia ventricular con compromiso hemodinámico y/o fibrilación ventricular (prevención secundaria) <a href="#2"><sup>2,3</sup></a> grupo con alto riesgo de recurrencia y en quienes esta terapia ha demostrado disminución significativa de la mortalidad. En prevención primaria, es decir en pacientes que no han tenido muerte súbita o taquiarritmias ventriculares pero que se consideran de alto riesgo, también hay evidencia clara de su beneficio <a href="#4"><sup>4,5,6</sup></a>. Este grupo sin embargo, es heterogéneo y no todos aquellos pacientes a quienes se implanta el desfibrilador presentan eventos durante el seguimiento. Considerando los costos y las potenciales complicaciones relacionadas al implante, en este momento se están valorando diferentes marcadores de predicción (variabilidad de la frecuencia cardíaca, turbulencia de la frecuencia cardíaca o alternancia de la onda t) que permitan seleccionar con mayor predicción a los pacientes <a href="#7"><sup>7</sup></a>.    <br> </font></p>     <p><font face="Arial" size="2">El avance tecnológico ha permitido que estos dispositivos se implanten en la región pectoral <a href="#f1">(figura 1)</a>sin necesidad de anestesia general y que tengan otras funciones además de las terapias antitaquicardia como son terapia antibradicardia bicameral y sincronización biventricular <a href="#8"><sup>8</sup></a> . El funcionamiento básico de estos dispositivos incluye un sistema de detección, basado en diversas instrucciones que a modo de algoritmo, determina si las señales intracardíacas detectadas corresponden o no a una taquiarritmia ventricular y un sistema de estimulación que mediante diversos parámetros programados, aplica una terapia antitaquicardia si corresponde. Las terapias antitaquicardia son estimulación antitaquicardia, cardioversión y desfibrilación <a href="#9"><sup>9</sup></a> <a href="#f2">(figura 2)</a>.    <br> </font></p>     <p style="text-align: center;"><font face="Arial" size="2"><a name="f1"></a><img  src="/img/fbpe/rcc/v6n3/2748i1.JPG" title="" alt=""  style="width: 409px; height: 357px;"></font></p>     
<p style="text-align: center;"><font face="Arial" size="2"><a name="f2"></a><img  src="/img/fbpe/rcc/v6n3/2748i2.JPG" title="" alt=""  style="width: 596px; height: 565px;">    
<br> </font></p>     <p style="text-align: left;"><font face="Arial" size="2"><b>Figura 2. A.</b> Estimulación antitaquicardia. Se muestran tres derivaciones electrocardiográficas I, II y III. Una vez diagnosticado el ritmo como taquicardia ventricular (la mitad izquierda del trazado), el dispositivo estimula a modo de marcapasos pero a una frecuencia superior a la de la taquicardia (se ven las espigas seguidas de complejos QRS al centro), lo que permite su interrupción y restablecimiento del ritmo sinusal normal (últimos 4 latidos del trazado). B. Las derivaciones superior e inferior son trazados endocavitarios en ambos ventrículos, entre ambos el canal de marcas e interpretación de las señales por el dispositivo. Detección de una fibrilación ventricular y la consiguiente administración de 30 Joules (flecha)retornándose a ritmo sinusal normal (el siguiente latido)y luego ritmo de marcapasos.</font></p>     <p><font face="Arial" size="2"> </font></p>     ]]></body>
<body><![CDATA[<p><font face="Arial" size="2">    <br> Existen varios algoritmos actualmente disponibles que utilizan diversos criterios con el fin de diagnosticar una taquiarritmia ventricular <a  href="#10"><sup>10</sup></a> . El <i>criterio de frecuencia </i>consiste en que sobrepasado un determinado límite (p.ej, 180 lpm)el dispositivo diagnostica taquicardia ventricular (TV)o fibrilación ventricular (FV)y administra la terapia. El <i>criterio morfológico </i>se basa en qué tan diferente es la señal intracardíaca actual comparada con una señal previamente almacenada durante ritmo sinusal normal, incluyendo pacientes que tienen bloqueo de rama del haz de His. La <i>estabilidad </i>se refiere a la variación del intervalo RR: por encima de un límite programado se diagnostica fibrilación atrial o extrasísitoles. Cuando se comparan las señales atrial y ventricular en los dispositivos de doble cámara, al establecer la <i>relación AV </i>mediante algoritmos prestablecidos se diagnostica TV/FV por la presencia de disociación AV o bien que se trata de un ritmo supraventricular <a href="#10"><sup>10</sup></a> . </font></p>     <p><font face="Arial" size="2">Si bien estos ingeniosos algoritmos han demostrado utilidad, no están exentos de errores en la <i>discriminación del ritmo subyacente </i>, de manera que pueden diagnosticar erróneamente TV o FV, caso en el cual, el dispositivo aplica terapias en forma inadecuada o injustificada. Así, puede confundirse una taquicardia sinusal o una taquicardia supraventricular, en especial, fibrilación atrial y diagnosticarse una taquiarritmia ventricular, usualmente cuando varían las condiciones basales del paciente, tales como cambios en el patrón de actividad, uso de antiarrítmicos o progresión de la cardiopatía de fondo. También puede ocurrir por <i>sobredetección </i>de la <i>onda t </i>contabilizándose dos veces un mismo latido, con lo que se alcanza entonces el criterio de frecuencia para TV/FV o por <i>sobredetección de señales eléctricas externas </i>como miopotenciales de músculos abdominales por defectos en el aislamiento de los electrodos o señales eléctricas externas de artefactos eléctricos sin conexión a tierra (interferencia electromagnética)u otros fallos debidos a raros errores de fabricación (ver discusión). </font></p>     <p><font face="Arial" size="2">Estas terapias inadecuadas pueden incluso inducir TV o FV produciéndose múltiples choques, reducir la vida útil de la batería y afectar la calidad de vida del paciente. El objetivo del presente estudio es conocer la prevalencia de terapias inadecuadas en los pacientes portadores de cardiodesfibriladores implantables que se han controlado en la clínica de arritmias de nuestro centro en el período junio-2002 a julio-2004. </font></p> <font face="Arial" size="2"><b>     <p>    <br> Materiales y métodos. </p> </b> <u></u></font>     <p><font face="Arial" size="2"><u>Pacientes</u>: Se incluyeron todos los pacientes portadores de cardiodesfibrilador que acudieron a la clínica de arritmias de nuestro centro, independientemente del lugar y fecha del implante. Los pacientes acudieron con motivo de sus controles regulares ambulatorios o bien en forma extemporánea por haber recibido terapias (choques). </font></p> <font face="Arial" size="2"><u></u></font>     <p><font face="Arial" size="2"><u>Registro</u>: A todos los pacientes se les realizó sistemáticamente interrogación por telemetría contabilizándose todos los eventos registrados. Se estableció mediante los electrogramas almacenados si la terapia enviada por el dispositivo era adecuada o no, según la taquiarritmia diagnosticada, según el criterio del médico a cargo de la interrogación. </font></p> <font face="Arial" size="2"><b>     <p>    <br> Resultados</p> </b> </font>     ]]></body>
<body><![CDATA[<p><font face="Arial" size="2">Se registraron 99 eventos almacenados en 16 pacientes durante el período de estudio. El número total de visitas a la clínica de marcapasos fue 33 (2. 05 visitas/paciente). Las edades fluctuaron entre 26 y 74 años (pormedio 48.18) siendo 13 de sexo masculino. Los diagnósticos y eventos se anotan en la <a href="#t1"><b>tabla 1</b></a>.    <br> </font></p>     <p style="text-align: center;"><font face="Arial" size="2"><a name="t1"></a><img  src="/img/fbpe/rcc/v6n3/2748i5.JPG" title="" alt=""  style="width: 564px; height: 426px;">    
<br> </font></p>     <p><font face="Arial" size="2">De los 99 eventos registrados, se consideró 22 como inadecuados (22.22%); el paciente (#3)portador de una displasia arritmogénica del ventrículo derecho tuvo 64 cardioversiones adecuadas el mismo día, debidas a un cuadro febril y repetidos episodios de taquicardia ventricular. El paciente #15 tuvo 17 cardioversiones el mismo día debidas a fibrilación atrial aguda mal diagnosticada como TV. Excluyendo estos dos casos de múltiples choques debidos prácticamente a un solo episodio arrítmico, la prevalencia de terapias inadecuadas es del 45.45% (5 terapias inadecuadas de 11 terapias en total)</font></p>     <p><font face="Arial" size="2">Las terapias inadecuadas fueron: taquicardia sinusal interpretada como ventricular (2 pacientes, #1 y 2, <a href="#f3"><b>figura 3</b></a>), fibrilación atrial aguda interpretada como fibrilación ventricular (19 eventos en 2 pacientes, #6 y 15,<a  href="#f4"> <b>figura 4</b></a>) y sobresensado de onda T (1 paciente #4,<a href="#f5"> <b>figura 5</b></a>).    <br> </font></p>     <p style="text-align: center;"><font face="Arial" size="2"><a name="f3"></a><img  src="/img/fbpe/rcc/v6n3/2748i3.JPG" title="" alt=""  style="width: 594px; height: 526px;">    
<br> </font></p>     <p><font face="Arial" size="2"><b>Figura 3.</b> Episodio de taquicardia sinusal que es interpretado como fibrilación ventricular. En A se muestran dos canales endocavitarios, la actividad atrial y la ventricular, demostrándose que se conserva la secuencia atrioventricular normal (ritmo sinusal). El canal inferior muestra la interpretación de los eventos por el dispositivo y la duración de los intervalos en milisegundos. En B , alcanzada una frecuencia cardíaca por encima de la cual se programó que se diagnostique fibrilación ventricular (FS, señalado con flechas), se aplica desfibrilación con 23.5 J (flecha en C ), sin variación en el ritmo subyacente.    ]]></body>
<body><![CDATA[<br> </font></p>     <p style="text-align: center;"><font face="Arial" size="2"><a name="f4"></a><img  src="/img/fbpe/rcc/v6n3/2748i4.JPG" title="" alt=""  style="width: 552px; height: 440px;">    
<br> </font></p>     <p><font face="Arial" size="2"><b>Figura 4. A:</b> Episodio de fibrilación atrial interpretado como fibrilación ventricular. Los canales mostrados son los mismos que en la figura 3 . La ampliación en B muestra la presencia de un ritmo rápido e irregular a nivel atrial (ondas f)con una frecuencia ventricular elevada e irregular. Erróneamente es interpretado como taquicardia ventricular, por lo que el dispositivo administra una descarga de 30. 2 joules (flecha en C )sin variación en el ritmo subyacente.    <br> </font></p>     <p style="text-align: center;"><font face="Arial" size="2"><a name="f5"></a><img  src="/img/fbpe/rcc/v6n3/2748i6.JPG" title="" alt=""  style="width: 707px; height: 438px;">    
<br> </font></p>     <p><font face="Arial" size="2"><b>Figura 5.</b> Episodio de taquicardia sinusal que es interpretado como fibrilación ventricular debido a doble conteo originado en la onda T. En A se muestran dos canales endocavitarios, en el superior la actividad atrial y en el inferior la ventricular, mostrándose la secuencia atrioventricular sinusal normal a una frecuencia de alrededor de 100 lpm. El canal inferior muestra la interpretación de los eventos por el dispositivo y la duración de los intervalos en milisegundos. En B se demuestra que la onda t de cada complejo qrs es detectada como si fuera una contracción ventricular. Al hacer un doble conteo, la frecuencia cardiaca así calculada cae en el rango programado para diagnosticar de fibrilación ventricular (FS, señalado con flechas), por lo que el dispositivo administra la terapia con 21 joules (flecha en C )sin variación en el ritmo subyacente.</font></p>     <p><font face="Arial" size="2">Un paciente con el electrodo atrial mal posicionado detectaba actividad ventricular como si fuera atrial (#14). Por este motivo, cuando tuvo taquicardia ventricular el dispositivo estableció una pseudorelación AV 1 a 1 llevando al diagnóstico erróneo de taquicardia supraventricular recibiendo entonces terapias en forma intermitente. Este paciente no fue incluido en el análisis ya que es un caso de subsensado o subdetección y no de terapia inadecuada, sin embargo las terapias que recibió se consideraron adecuadas y se incluyó en el análisis de todo el grupo. </font></p>     <p><font face="Arial" size="2">No hubo ningún caso ocasionado por inter ferencia electromagnética o alteración en el funcionamiento de los electrodos. </font></p> <font face="Arial" size="2"><b>     ]]></body>
<body><![CDATA[<p>    <br> Discusión</p> </b> </font>     <p><font face="Arial" size="2">En el presente estudio, la prevalencia de errores diagnósticos en desfibriladores es relativamente alta. La prevalencia reportada inicialmente en la literatura fue alrededor del 22%de los pacientes, predominando las taquicardias supraventriculares como el evento desencadenante mas frecuente <a href="#11"><sup>11</sup></a> . En publicaciones más recientes, con uso de dispositivos con mayor avance tecnológico, fluctúa entre un 15 y 40% <a href="#12"><sup>12, 13, 14, 15</sup></a> , cifras comparables a las de nuestro centro. </font></p>     <p><font face="Arial" size="2">Se han descrito múltiples causas de terapia inapropiada. Ellas incluyen el sobresensado de miopotenciales mal interpretados como fibrilación ventricular <a href="#16"><sup>16</sup></a> , taquicardias supraventriculares <a href="#11"><sup>11, 12</sup></a> , taquicardia ventricular no sostenida pero que no evita la administración de la terapia, sobredetección de la onda t considerada como una contracción ventricular <a href="#17"><sup>17</sup></a>, defectos en el aislamiento o dislocación de los electrodos <a href="#18"><sup>18</sup></a> , fallos en el circuito electrónico <a href="#19"><sup>19</sup></a> , extrasístoles ventriculares que aparecen a un intervalo crítico durante el período de reconfirmación o de "segunda revisión" <sup><a  href="#12">12</a>, <a href="#20">20, 21</a></sup> o hélice incompletamente desenrrollado <a  href="#22"><sup>22</sup></a> . En desfibriladores implantables con estimulación biventricular se ha descrito doble sensado (o doble conteo) cuando este es realizado por ambos electrodos <a href="#23"><sup>23, 24</sup></a> . </font></p>     <p><font face="Arial" size="2">También se consideran disfunción los casos de inducción de TV/FV por un shock inadecuado originado en una taquicardia supraventricular con incapacidad del dispositivo para terminar la arritmia inducida <a href="#25"><sup>25</sup></a> , inactivación inadvertida del circuito de como si fuera atrial (#14). Por este motivo, cuando tuvo taquicardia ventricular el dispositivo estableció una pseudorelación AV 1 a 1 llevando al diagnóstico erróneo de inhibición de terapias con magneto <a href="#26"><sup>26</sup></a> , defectos que provocan tiempo excesivo de carga de los capacitores <a href="#27"><sup>27</sup></a> , errores en los algoritmos y programas de computación ("software ") <sup><a href="#28">28</a> </sup>y sobresensado por hiperpolarización del electrodo <a href="#29"><sup>29</sup></a> . El fenómeno de hiperpolarización ocurre cuando por efecto de la administración de corriente a través del electrodo, iones positivos del tejido circundante se acumulan alrededor de él, interfiriendo con la adecuada detección de señales intracardíacas. </font></p>     <p><font face="Arial" size="2">Dado que los defectos de fabricación son resueltos rápidamente por las compañías manufactureras, se investigan mejorías en los algoritmos que diferencien taquicardias supraventriculares de las ventriculares <a href="#30"><sup>30, 31, 32</sup></a> ya que estos errores diagnósticos son la causa más frecuente <a href="#33"><sup>33</sup></a> de terapias inadecuadas que además de afectar la vida útil de la batería, afectan la calidad de vida de los pacientes. </font></p>     <p><font face="Arial" size="2">La limitación más importante de este estudio es el reducido número de pacientes y el reducido número de terapias, debido probablemente a que en su mayoría son pacientes jóvenes con cardiopatías que presentan eventos arrítmicos menos frecuentemente que en aquellos con enfermedad arterial coronaria. </font></p>     <p><font face="Arial" size="2">En <b>conclusión</b> , la prevalencia de terapias inadecuadas es relativamente frecuente y la más común en esta serie fue la fibrilación atrial interpretada como fibrilación ventricular debidas a errores en la discriminación. Este hallazgo sugiere que deben utilizarse todos los recursos de programación combinados con otras terapias para evitar estos errores diagnósticos. </font></p> <font face="Arial" size="2"><b>     <p>    <br> Bibliografía: </p> </b><i> </i></font>     ]]></body>
<body><![CDATA[<!-- ref --><p><font face="Arial" size="2"><a name="1"></a>1. Gregoratos G, Abrams J, Epstein AE et al: ACC/AHA/NASPE 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devices. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to update the 1998 practice guidelines). Circulation 2002; 106: 2145-2161.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741455&pid=S1409-4142200400030000300001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="2"></a></font><font face="Arial"  size="2">2. The Antiarrhythmic Versus Implantable Defibrilllator (AVID)investigators: A comparision of Antiarrhythmic-drug Therapy with Implantable Defibrillators in patients Resuscitated from Near-fatal Ventricular Arrhythmias. N Engl J Med 1997; 337: 1576.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741456&pid=S1409-4142200400030000300002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="3"></a></font><font face="Arial"  size="2">3. Kuck KH, Cappato R, Siebels J et al. Randomized comparision of antiarrhythmic drug therapy with implantable defibrillators in patients resucitated from cardiac arrest: The cardiac arrest study Hamburg (CASH). Circulation 2000; 102: 748-54</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741457&pid=S1409-4142200400030000300003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="4"></a></font><font face="Arial"  size="2">4. Moss AJ, Hall WJ, Cannomm DS et al. Improved survival with an implanted defibrillator in patients with coronary disease at high risk of ventricular arrhythmia (for the multicenter automatic defibrillator implantation trial investigators). N Engl J Med 1996; 335; 1933-40</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741458&pid=S1409-4142200400030000300004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="5"></a></font><font face="Arial"  size="2">5. Buxton AE, Lee KL, Fisher JD et al. A randomized study of the prevention of sudden death in patients with coronary artery disease. Multicenter unsustained tachycardia trial. N Engl J Med 1999; 341: 1882-90.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741459&pid=S1409-4142200400030000300005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="6"></a></font><font face="Arial"  size="2">6. Moss AJ, Zareba W, Hall WJ et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med 2002; 346: 877-883.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741460&pid=S1409-4142200400030000300006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="7"></a></font><font face="Arial"  size="2">7. Brenan FJ. Ethical Issues with Implantable defibrillators (editorial). Pacing and Clin Electrophys 2004; 27: 897-898.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741461&pid=S1409-4142200400030000300007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="8"></a></font><font face="Arial"  size="2">8. Esquivel L, Gutiérrez O. Terapia eléctrica de las arritmias cardiacas. Acta Médica costarricense 2004; 1.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741462&pid=S1409-4142200400030000300008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="9"></a></font><font face="Arial"  size="2">9. Gutiérrez O, Araya V. Manual de arritmias cardiacas. Guía diagnóstica y terapéutica. Editorial de la Universidad de Costa Rica, San José 2002; 269 pp; capítulo 10.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741463&pid=S1409-4142200400030000300009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="10"></a></font><font  face="Arial" size="2">10. Aliot E, Nitzsche R, Ripart A. Arrhythmia detection by dual-chamber implantable cardioverter defibrillators. A review of current algorithms. Europace 2004; 6: 273-286.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741464&pid=S1409-4142200400030000300010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="11"></a></font><font  face="Arial" size="2">11. Grimm W, Flores BF, Marchlinski FE. Electrocardiographically documented unnecessary, spontaneous shocks in 241 patients with implantable cardioverter defibrillators. Pacing Clin Electrophysiol 1992; 15: 1667-73.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741465&pid=S1409-4142200400030000300011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="12"></a></font><font  face="Arial" size="2">12. Goldberger JJ, Horvath G, Challapalli R, Kadish AH. Inappropriate implantable cardioverter-defibrillator therapy due to the detection of premature ventricular complexes. Pacing Clin Electrophysiol 1999; 22: 825-8.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741466&pid=S1409-4142200400030000300012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="13"></a></font><font  face="Arial" size="2">13. Weber M, Block M, Brunn J, Bansch D, Bocker D, Hammel D, Gietzen F, Breithardt G. Inadequate therapies with implantable cardioverter- defibrillators: incidence, etiology, predictive factors and preventive strategies Z Kardiol 1996; 85: 809-19.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741467&pid=S1409-4142200400030000300013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="14"></a></font><font  face="Arial" size="2">14. Nanthakumar K, Dorian P, Paquette M, Greene M, Edwards J, Heng D, Noble J, Newman D. Is inappropriate implantable defibrillator shock therapy predictable? Interv Card Electrophysiol. 2003; 8: 215-20.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741468&pid=S1409-4142200400030000300014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="15"></a></font><font  face="Arial" size="2">15. Gradaus R, Block M, Brachmann J, Breithardt G, Huber HG, Jung W, Kranig W, Mletzko RU, Schoels W, Seidl K, Senges J, Siebels J, Steinbeck G, Stellbrink C, Andersen D. German EURID Registry. Mortality, morbidity, and complications in 3344 patients with implantable cardioverter defibrillators: results from the German ICD Registry EURID. Pacing Clin Electrophysiol 2003; 26: 1511-8.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741469&pid=S1409-4142200400030000300015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="16"></a></font><font  face="Arial" size="2">16. Karanam S, John RM. Inappropriate sensing of pectoral myopotentials by an implantable cardioverter defibrillator system. Pacing Clin Electrophysiol 2004; 27: 688-9.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741470&pid=S1409-4142200400030000300016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="17"></a></font><font  face="Arial" size="2">17. Washizuka T, Chinushi M, Kasai H, Watanabe H, Tagawa M, Hosaka Y, Abe A, Aizawa Y. Inappropriate discharges from an intravenous implantable cardioverter defibrillator due to T-wave oversensing. Jpn Circ J. 2001; 65: 685-7.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741471&pid=S1409-4142200400030000300017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="18"></a></font><font  face="Arial" size="2">18. Tiroke A, Ganeeva ON, Syrkin AL. Unmotivated malfunction of implanted cardioverter-defibrillator and ways of its correction. Klin Med (Mosk). 2003; 81: 26-30.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741472&pid=S1409-4142200400030000300018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="19"></a></font><font  face="Arial" size="2">19. Zaim S, Sunthorn H, Adatte JJ, Kursteiner K, Burgener D, Huehn C. Inappropriate high-rate ventricular pacing in a patient with a defibrillator. Europace. 2002; 4: 427-30. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741473&pid=S1409-4142200400030000300019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="20"></a></font><font  face="Arial" size="2">20. Healy E, Ngarmukos T, Rosenthal L. A case of bad timing: inappropriate implantable cardioverter defibrillator therapy due to a critically placed premature ventricular contraction. Pacing Clin Electrophysiol. 2002; 25: 1403-5.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741474&pid=S1409-4142200400030000300020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="21"></a></font><font  face="Arial" size="2">21. Goldberger JJ, Horvath G, Challapalli R, Kadish AH. Inappropriate implantable cardioverter-defibrillator therapy due to the detection of premature ventricular complexes. Pacing Clin Electrophysiol 1999; 22: 825-8.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741475&pid=S1409-4142200400030000300021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="22"></a></font><font  face="Arial" size="2">22. Mela T, Ngarmukos T, Rosenthal L, Mittleman R. Inappropriate ICD therapy due to lead-related noise in an active fixation ICD lead. J Invasive Cardiol. 2001; 13: 406-8.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741476&pid=S1409-4142200400030000300022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p><font face="Arial" size="2"> </font></p>     <!-- ref --><p><font face="Arial" size="2"><a name="23"></a></font><font  face="Arial" size="2">23. Srivathsan K, Bazzell JL, Lee RW. Biventricular implantable cardioverter defibrillator and inappropriate shocks. J Cardiovasc Electrophysiol. 2003; 14: 88-9.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741478&pid=S1409-4142200400030000300023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="24"></a></font><font  face="Arial" size="2">24. Boriani G, Biffi M, Frabetti L, Parlapiano M, Galli R, Branzi A, Magnani B. Cardioverter-defibrillator oversensing due to double counting of ventricular tachycardia electrograms. Int J Cardiol 1998; 66: 91-5. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741479&pid=S1409-4142200400030000300024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="25"></a></font><font  face="Arial" size="2">25. Kuhlkamp V, Dornberger V, Mermi J, Mewis C, Seipel L. Shock-induced, but not terminated ventricular tachycardia in a patient with implantable defibrillator Z Kardiol 1996; 85: 306-11.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741480&pid=S1409-4142200400030000300025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="26"></a></font><font  face="Arial" size="2">26. Hunn RH, Ashbaugh TJ, Calderini M, Anderson KP. Multiple inappropriate shocks precipitated by interrogation of an implantable cardioverter defibrillator. Pacing Clin Electrophysiol 1998; 21: 1329-30.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741481&pid=S1409-4142200400030000300026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="27"></a></font><font  face="Arial" size="2">27. de Meester A, Gilles PH. ICD malfunction caused by excessive defibrillation charge time. Pacing Clin Electrophysiol. 2001; 24: 518-9.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741482&pid=S1409-4142200400030000300027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="28"></a></font><font  face="Arial" size="2">28. Coppess MA, Miller JM, Zipes DP, Groh WJ. Software error resulting in malfunction of an implantable cardioverter defibrillator. J Cardiovasc Electrophysiol 1999; 10: 871-3.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741483&pid=S1409-4142200400030000300028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="29"></a></font><font  face="Arial" size="2">29. Healy E, Goyal S, Browning C, Robotis D, Ramaswamy K, Rofino-Nadoworny K, Rosenthal L. Inappropriate ICD therapy due to proarrhythmic ICD shocks and hyperpolarization. Pacing Clin Electrophysiol. 2004; 27: 415-6.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741484&pid=S1409-4142200400030000300029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="30"></a></font><font  face="Arial" size="2">30. Schmitt C, Montero M, Melichercik J. Significance of supraventricular tachyarrhythmias in patients with implanted pacing cardioverter defibrillators. Pacing Clin Electrophysiol. 1994; 17: 295-302.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741485&pid=S1409-4142200400030000300030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="31"></a></font><font  face="Arial" size="2">31. Brugada J. Is inappropriate therapy a resolved issue with current implantable cardioverter defibrillators?Am J Cardiol 1999; 83: 40D-44D.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741486&pid=S1409-4142200400030000300031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="32"></a></font><font  face="Arial" size="2">32. Nanthakumar K, Paquette M, Newman D, Deno DC, Malden L, Gunderson B, Gilkerson J, Greene M, Heng D, Dorian P. Inappropriate therapy from atrial fibrillation and sinus tachycardia in automated implantable cardioverter defibrillators. Am Heart J. 2000; 139: 797-803.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741487&pid=S1409-4142200400030000300032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p><font face="Arial" size="2"><a name="33"></a></font><font  face="Arial" size="2">33. Stein KM, Euler DE, Mehra R, Seidl K, Slotwiner DJ, Mittal S, Markowitz SM, Lerman BB; Jewel AF Worldwide Investigators. Do atrial tachyarrhythmias beget ventricular tachyarrhythmias in defibrillator recipients?J Am Coll Cardiol. 2002; 40: 335-40.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741488&pid=S1409-4142200400030000300033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><br> </span><font face="Arial" size="2"><a name="a02"></a></font><font  face="Arial" size="2">Cardiólogo-electrofisiólogo. Servicio de Cardiología, sección 4-B, Hospital México, C.C.S.S., San José, Costa Rica. Apartado Postal 471-1300, San José, Costa Rica. Teléfono: (506)368-2049 e-mail: <a href="mailto:oswcr@hotmail.com">oswcr@hotmail.com</a></font>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gregoratos]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Abrams]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Epstein]]></surname>
<given-names><![CDATA[AE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[ACC/AHA/NASPE 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devices: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to update the 1998 practice guidelines)]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2002</year>
<volume>106</volume>
<page-range>2145-2161</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<article-title xml:lang="en"><![CDATA[The Antiarrhythmic Versus Implantable Defibrilllator (AVID)investigators: A comparision of Antiarrhythmic-drug Therapy with Implantable Defibrillators in patients Resuscitated from Near-fatal Ventricular Arrhythmias]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>1997</year>
<volume>337</volume>
<page-range>1576</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kuck]]></surname>
<given-names><![CDATA[KH]]></given-names>
</name>
<name>
<surname><![CDATA[Cappato]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Siebels]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Randomized comparision of antiarrhythmic drug therapy with implantable defibrillators in patients resucitated from cardiac arrest: The cardiac arrest study Hamburg (CASH)]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2000</year>
<volume>102</volume>
</nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moss]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
<name>
<surname><![CDATA[Hall]]></surname>
<given-names><![CDATA[WJ]]></given-names>
</name>
<name>
<surname><![CDATA[Cannomm]]></surname>
<given-names><![CDATA[DS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Improved survival with an implanted defibrillator in patients with coronary disease at high risk of ventricular arrhythmia (for the multicenter automatic defibrillator implantation trial investigators)]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>1996</year>
<volume>335</volume>
<page-range>1933-40</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Buxton]]></surname>
<given-names><![CDATA[AE]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[KL]]></given-names>
</name>
<name>
<surname><![CDATA[Fisher]]></surname>
<given-names><![CDATA[JD]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A randomized study of the prevention of sudden death in patients with coronary artery disease: Multicenter unsustained tachycardia trial]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>1999</year>
<volume>341</volume>
<page-range>1882-90</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moss]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
<name>
<surname><![CDATA[Zareba]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Hall]]></surname>
<given-names><![CDATA[WJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>2002</year>
<volume>346</volume>
<page-range>877-883</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brenan]]></surname>
<given-names><![CDATA[FJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ethical Issues with Implantable defibrillators (editorial)]]></article-title>
<source><![CDATA[Pacing and Clin Electrophys]]></source>
<year>2004</year>
<volume>27</volume>
<page-range>897-898</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Esquivel]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Gutiérrez]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Terapia eléctrica de las arritmias cardiacas]]></article-title>
<source><![CDATA[Acta Médica costarricense]]></source>
<year>2004</year>
<volume>1</volume>
</nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gutiérrez]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Araya]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<source><![CDATA[Manual de arritmias cardiacas: Guía diagnóstica y terapéutica]]></source>
<year>2002</year>
<page-range>269</page-range><publisher-loc><![CDATA[San José ]]></publisher-loc>
<publisher-name><![CDATA[Editorial de la Universidad de Costa Rica]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aliot]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Nitzsche]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Ripart]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Arrhythmia detection by dual-chamber implantable cardioverter defibrillators: A review of current algorithms]]></article-title>
<source><![CDATA[Europace]]></source>
<year>2004</year>
<volume>6</volume>
<page-range>273-286</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Grimm]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Flores]]></surname>
<given-names><![CDATA[BF]]></given-names>
</name>
<name>
<surname><![CDATA[Marchlinski]]></surname>
<given-names><![CDATA[FE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrocardiographically documented unnecessary, spontaneous shocks in 241 patients with implantable cardioverter defibrillators]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>1992</year>
<volume>15</volume>
<page-range>1667-73</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Goldberger]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
<name>
<surname><![CDATA[Horvath]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Challapalli]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Kadish]]></surname>
<given-names><![CDATA[AH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Inappropriate implantable cardioverter-defibrillator therapy due to the detection of premature ventricular complexes]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>1999</year>
<volume>22</volume>
<page-range>825-8</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Weber]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Block]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Brunn]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Bansch]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Bocker]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Hammel]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Gietzen]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Breithardt]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Inadequate therapies with implantable cardioverter- defibrillators: incidence, etiology, predictive factors and preventive strategies]]></article-title>
<source><![CDATA[Z Kardiol]]></source>
<year>1996</year>
<volume>85</volume>
<page-range>809-19</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nanthakumar]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Dorian]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Paquette]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Greene]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Edwards]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Heng]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Noble]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Newman]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Is inappropriate implantable defibrillator shock therapy predictable?]]></article-title>
<source><![CDATA[Interv Card Electrophysiol]]></source>
<year>2003</year>
<volume>8</volume>
<page-range>215-20</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gradaus]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Block]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Brachmann]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Breithardt]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Huber]]></surname>
<given-names><![CDATA[HG]]></given-names>
</name>
<name>
<surname><![CDATA[Jung]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Kranig]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Mletzko]]></surname>
<given-names><![CDATA[RU]]></given-names>
</name>
<name>
<surname><![CDATA[Schoels]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Seidl]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Senges]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Siebels]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Steinbeck]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Stellbrink]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Andersen]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[German EURID Registry. Mortality, morbidity, and complications in 3344 patients with implantable cardioverter defibrillators: results from the German ICD Registry EURID]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2003</year>
<volume>26</volume>
<page-range>1511-8</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Karanam]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[John]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Inappropriate sensing of pectoral myopotentials by an implantable cardioverter defibrillator system]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2004</year>
<volume>27</volume>
<page-range>688-9</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Washizuka]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Chinushi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Kasai]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Watanabe]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Tagawa]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Hosaka]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Abe]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Aizawa]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Inappropriate discharges from an intravenous implantable cardioverter defibrillator due to T-wave oversensing]]></article-title>
<source><![CDATA[Jpn Circ J]]></source>
<year>2001</year>
<volume>65</volume>
<page-range>685-7</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tiroke]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Ganeeva]]></surname>
<given-names><![CDATA[ON]]></given-names>
</name>
<name>
<surname><![CDATA[Syrkin]]></surname>
<given-names><![CDATA[AL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Unmotivated malfunction of implanted cardioverter-defibrillator and ways of its correction]]></article-title>
<source><![CDATA[Klin Med (Mosk)]]></source>
<year>2003</year>
<volume>81</volume>
<page-range>26-30</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zaim]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Sunthorn]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Adatte]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
<name>
<surname><![CDATA[Kursteiner]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Burgener]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Huehn]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Inappropriate high-rate ventricular pacing in a patient with a defibrillator]]></article-title>
<source><![CDATA[Europace]]></source>
<year>2002</year>
<volume>4</volume>
<page-range>427-30</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Healy]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Ngarmukos]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Rosenthal]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A case of bad timing: inappropriate implantable cardioverter defibrillator therapy due to a critically placed premature ventricular contraction]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2002</year>
<volume>25</volume>
<page-range>1403-5</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Goldberger]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
<name>
<surname><![CDATA[Horvath]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Challapalli]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Kadish]]></surname>
<given-names><![CDATA[AH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Inappropriate implantable cardioverter-defibrillator therapy due to the detection of premature ventricular complexes]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>1999</year>
<volume>22</volume>
<page-range>825-8</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mela]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Ngarmukos]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Rosenthal]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Mittleman]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Inappropriate ICD therapy due to lead-related noise in an active fixation ICD lead]]></article-title>
<source><![CDATA[J Invasive Cardiol]]></source>
<year>2001</year>
<volume>13</volume>
<page-range>406-8</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Srivathsan]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Bazzell]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[RW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biventricular implantable cardioverter defibrillator and inappropriate shocks]]></article-title>
<source><![CDATA[J Cardiovasc Electrophysiol]]></source>
<year>2003</year>
<volume>14</volume>
<page-range>88-9</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Boriani]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Biffi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Frabetti]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Parlapiano]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Galli]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Branzi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Magnani]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cardioverter-defibrillator oversensing due to double counting of ventricular tachycardia electrograms]]></article-title>
<source><![CDATA[Int J Cardiol]]></source>
<year>1998</year>
<volume>66</volume>
<page-range>91-5</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kuhlkamp]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Dornberger]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Mermi]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Mewis]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Seipel]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Shock-induced, but not terminated ventricular tachycardia in a patient with implantable defibrillator]]></article-title>
<source><![CDATA[Z Kardiol]]></source>
<year>1996</year>
<volume>85</volume>
<page-range>306-11</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hunn]]></surname>
<given-names><![CDATA[RH]]></given-names>
</name>
<name>
<surname><![CDATA[Ashbaugh]]></surname>
<given-names><![CDATA[TJ]]></given-names>
</name>
<name>
<surname><![CDATA[Calderini]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Anderson]]></surname>
<given-names><![CDATA[KP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Multiple inappropriate shocks precipitated by interrogation of an implantable cardioverter defibrillator]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>1998</year>
<volume>21</volume>
<page-range>1329-30</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[de Meester]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Gilles]]></surname>
<given-names><![CDATA[PH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[ICD malfunction caused by excessive defibrillation charge time]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2001</year>
<volume>24</volume>
<page-range>518-9</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Coppess]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Miller]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Zipes]]></surname>
<given-names><![CDATA[DP]]></given-names>
</name>
<name>
<surname><![CDATA[Groh]]></surname>
<given-names><![CDATA[WJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Software error resulting in malfunction of an implantable cardioverter defibrillator]]></article-title>
<source><![CDATA[J Cardiovasc Electrophysiol]]></source>
<year>1999</year>
<volume>10</volume>
<page-range>871-3</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Healy]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Goyal]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Browning]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Robotis]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Ramaswamy]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Rofino-Nadoworny]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Rosenthal]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Inappropriate ICD therapy due to proarrhythmic ICD shocks and hyperpolarization]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2004</year>
<volume>27</volume>
<page-range>415-6</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schmitt]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Montero]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Melichercik]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Significance of supraventricular tachyarrhythmias in patients with implanted pacing cardioverter defibrillators]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>1994</year>
<volume>17</volume>
<page-range>295-302</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brugada]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Is inappropriate therapy a resolved issue with current implantable cardioverter defibrillators?]]></article-title>
<source><![CDATA[Am J Cardiol]]></source>
<year>1999</year>
<volume>83</volume>
<page-range>40D-44D</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nanthakumar]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Paquette]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Newman]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Deno]]></surname>
<given-names><![CDATA[DC]]></given-names>
</name>
<name>
<surname><![CDATA[Malden]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Gunderson]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Gilkerson]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Greene]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Heng]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Dorian]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Inappropriate therapy from atrial fibrillation and sinus tachycardia in automated implantable cardioverter defibrillators]]></article-title>
<source><![CDATA[Am Heart J]]></source>
<year>2000</year>
<volume>139</volume>
<page-range>797-803</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stein]]></surname>
<given-names><![CDATA[KM]]></given-names>
</name>
<name>
<surname><![CDATA[Euler]]></surname>
<given-names><![CDATA[DE]]></given-names>
</name>
<name>
<surname><![CDATA[Mehra]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Seidl]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Slotwiner]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
<name>
<surname><![CDATA[Mittal]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Markowitz]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
<name>
<surname><![CDATA[Lerman]]></surname>
<given-names><![CDATA[BB]]></given-names>
</name>
<name>
<surname><![CDATA[Jewel]]></surname>
<given-names><![CDATA[AF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Worldwide Investigators: Do atrial tachyarrhythmias beget ventricular tachyarrhythmias in defibrillator recipients?]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2002</year>
<volume>40</volume>
<page-range>335-40</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
