<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1409-4142</journal-id>
<journal-title><![CDATA[Revista Costarricense de Cardiología]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. costarric. cardiol]]></abbrev-journal-title>
<issn>1409-4142</issn>
<publisher>
<publisher-name><![CDATA[Asociación Costarricense de Cardiología]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1409-41422003000300009</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Ecocardiografía doppler color en el tratamiento del seudoaneurisma femoral iatrogénico: a propósito de un caso]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Lanzoni Rodríguez]]></surname>
<given-names><![CDATA[Allan]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Centro Cardiológico Integral  ]]></institution>
<addr-line><![CDATA[San José ]]></addr-line>
<country>Costa Rica</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2003</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2003</year>
</pub-date>
<volume>5</volume>
<numero>3</numero>
<fpage>51</fpage>
<lpage>53</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_arttext&amp;pid=S1409-41422003000300009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_abstract&amp;pid=S1409-41422003000300009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_pdf&amp;pid=S1409-41422003000300009&amp;lng=en&amp;nrm=iso"></self-uri></article-meta>
</front><body><![CDATA[  <B><FONT FACE="Arial"><FONT SIZE=-1>CASO CLINICO</FONT></FONT></B>     <CENTER></CENTER>      <CENTER><B><FONT FACE="Arial">Ecocardiograf&iacute;a doppler color en el tratamiento del seudoaneurisma femoral iatrog&eacute;nico:</FONT></B></CENTER>      <CENTER><B><FONT FACE="Arial">a prop&oacute;sito de un caso.</FONT></B></CENTER>      <CENTER>&nbsp;</CENTER>      <CENTER>&nbsp;</CENTER>      <CENTER><FONT FACE="Arial"><FONT SIZE=-1>Dr.Allan Lanzoni Rodr&iacute;guez&nbsp;<A NAME="*R"></A><A HREF="#*A">*</A></FONT></FONT></CENTER> &nbsp;     <BR>&nbsp;     <BR><FONT FACE="Arial"><FONT SIZE=-1>Los procedimientos cardiovasculares percut&aacute;neos diagn&oacute;sticos y terap&eacute;uticos se han convertido en la actualidad en una herramienta fundamental en la valoraci&oacute;n y tratamiento del paciente con enfermedad cardiovascular principalmente coronaria. Las complicaciones vasculares en el sitio de punci&oacute;n femoral en un cateterismo card&iacute;aco con o sin intervenci&oacute;n terap&eacute;utica se encuentran dentro de las complicaciones m&aacute;s comunes en estos procedimientos, destacando el hematoma femoral simple, el seudoaneurisma y la f&iacute;stula arteriovenosa, estos dos &uacute;ltimos con una incidencia de entre el 1 y el 14 % de los pacientes. Estas complicaciones requieren habitualmente tratamientos adicionales como son compresiones prolongadas, transfusiones, cirug&iacute;a y consecuentemente, estad&iacute;as hospitalarias m&aacute;s prolongadas y eventualmente incremento en mortalidad (<A HREF="#1">1</A>).</FONT></FONT>      <P><FONT FACE="Arial"><FONT SIZE=-1>Los procedimientos hemodin&aacute;micas en nuestro medio han experimentado un crecimiento exponencial producto de su valor creciente en la terap&eacute;utica, principalmente coronaria, pasando</FONT></FONT>      ]]></body>
<body><![CDATA[<P><FONT FACE="Arial"><FONT SIZE=-1>nuestro pa&iacute;s en un corto per&iacute;odo de tiempo de dos a seis laboratorios de hemodinamia. Adem&aacute;s, el uso de cat&eacute;teres e introductores de gran calibre en algunos procedimientos, y la utilizaci&oacute;n de protocolos agresivos de antiagregaci&oacute;n plaquetaria y anticoagulaci&oacute;n, han conllevado a un riesgo aumentado de complicaciones en el sitio de acceso arterial. En nuestro medio de forma tradicional los seudoaneurismas femorales han sido tratados de forma quir&uacute;rgica. Se presenta el caso de una paciente con un seudoaneurisma femoral tratado con compresi&oacute;n en el cuello del seudoaneurisma mediante ecocardiograf&iacute;a.</FONT></FONT>      <P><B><FONT FACE="Arial"><FONT SIZE=-1>Caso cl&iacute;nico</FONT></FONT></B>      <P><FONT FACE="Arial"><FONT SIZE=-1>Paciente femenina de 68 a&ntilde;os de edad, hipertensa y dislipid&eacute;mica como factores de riesgo coronarios, quien fue ingresada por cuadro de 15 d&iacute;as de evoluci&oacute;n de angina progresiva, realiz&aacute;ndosele una coronariograf&iacute;a que mostr&oacute; lesi&oacute;n del 95% de arteria descendente anterior proximal, intervini&eacute;ndose de forma inmediata con el implante de stent coronario de 3.5 mm sin lesi&oacute;n residual significativa, recibiendo tirofiban IV concomitantemente. El introductor fue retirado a las 12 horas por el residente del sal&oacute;n presentando un moderado sangrado y requiriendo compresi&oacute;n prolongada. La paciente continu&oacute; posteriormente con antiagregaci&oacute;n plaquetaria est&aacute;ndar a base de aspirina y clopidogrel. A los dos d&iacute;as se nota masa puls&aacute;til dolorosa en sitio de punci&oacute;n, con soplo a la auscultaci&oacute;n. Se realiz&oacute; US doppler de arteria femoral que confirma las sospecha cl&iacute;nica del seudoaneurisma y es referida a nuestro centro. Se realiza eco doppler color de arteria femoral derecha mediante ecocardi&oacute;grafo GE Vingmed modelo Vivid 5 y adquisici&oacute;n de im&aacute;genes mediante transductor lineal de 8 mHz y sectorial de 2.5 mHz que demuestra hematoma superficial de 6 cm de di&aacute;metro e inmediatamente al mismo se observa seudoaneurisma de 45 mm de di&aacute;metro mayor con flujo color de vaiv&eacute;n en su interior, dependiente de arteria femoral com&uacute;n (<B><A HREF="#fig1">figura 1</A></B>). La imagen espectral de flujo en el cuello del seudoaneurisma mostr&oacute; un flujo sist&oacute;lico entrante de alta velocidad (2.6 m/seg) y un flujo diast&oacute;lico decreciente de salida con velocidad m&aacute;xima de 1.1 m/seg <B>(<A HREF="#fig2">figura 2</A></B>). Previa analgesia IM de la paciente se procedi&oacute; a realizar compresi&oacute;n del cuello del seudoaneurisma por medio del transductor de ultrasonidos que permit&iacute;a graduar la compresi&oacute;n a una presi&oacute;n que permitiera el paso a trav&eacute;s de la arteria femoral profunda y que impidiera el flujo dentro del saco del seudoaneurisma <B>(<A HREF="#fig3">figura 3</A></B> ). Dicha compresi&oacute;n se mantuvo durante 25 minutos la cual fue retirada de forma progresiva mostrando m&iacute;nimo flujo en sitio de entrada del seudoaneurisma, sin observarse flujo mediante el doppler color en el 95% del mismo. Se realiz&oacute; control ecocardiogr&aacute;fico al quinto d&iacute;a que confirm&oacute; la trombosis completa del seudoaneurisma y flujo color normal en arteria femoral com&uacute;n <B>(<A HREF="#fig4">figura 4</A></B>). Control cl&iacute;nico a los dos meses del procedimiento mostr&oacute; ausencia del soplo femoral, endurecimiento anterior a la arteria femoral com&uacute;n como remanente del sitio del seudoaneurisma previo y movilidad normal de la pierna sin dolor.</FONT></FONT>     <BR><FONT FACE="Arial"><FONT SIZE=-1>&nbsp;</FONT></FONT>     <CENTER><A NAME="fig1"></A><IMG SRC="/img/fbpe/rcc/v5n3/2275i01.JPG" HEIGHT=483 WIDTH=307></CENTER>      
<CENTER>&nbsp;</CENTER>      <CENTER><A NAME="fig2"></A><IMG SRC="/img/fbpe/rcc/v5n3/2275i02.JPG" HEIGHT=257 WIDTH=331></CENTER>      
<CENTER>&nbsp;</CENTER>      <CENTER><A NAME="fig3"></A><IMG SRC="/img/fbpe/rcc/v5n3/2275i03.JPG" HEIGHT=476 WIDTH=330></CENTER>      
<CENTER>&nbsp;</CENTER>      ]]></body>
<body><![CDATA[<CENTER><A NAME="fig4"></A><IMG SRC="/img/fbpe/rcc/v5n3/2275i04.JPG" HEIGHT=450 WIDTH=327></CENTER>       
<P><B><FONT FACE="Arial"><FONT SIZE=-1>Discusi&oacute;n</FONT></FONT></B>      <P><FONT FACE="Arial"><FONT SIZE=-1>En las primeras series de cateterismos reportadas, la tasa de complicaciones vasculares perif&eacute;ricas era de hasta el 29% (<A HREF="#2">2</A>). La probabilidad de complicaciones perif&eacute;ricas del cateterismo card&iacute;aco se incrementa con la complejidad del procedimiento realizado, siendo entre el 0.5% al 1% en procedimientos diagn&oacute;sticos, del 0.9 al 9% con la angioplast&iacute;a con bal&oacute;n, entre el 5.7 y 17% con el implante de stent, del 5.2 al 10% en la valvuloplastia mitral con bal&oacute;n y del 10 al 37% en procedimientos complejos que connotan habitualmente la colocaci&oacute;n de contrapulsaci&oacute;n a&oacute;rtica. Las complicaciones femorales del cateterismo card&iacute;aco se pueden definir de la siguiente forma (<A HREF="#3">3</A>):</FONT></FONT>      <P><FONT FACE="Arial"><FONT SIZE=-1><B>Hematoma:</B> Tumoraci&oacute;n evidente a la palpaci&oacute;n en sitio de punci&oacute;n y habitualmente visible, que de acuerdo a su tama&ntilde;o se clasifican como ligeros a moderados aquellos de menos de 5 cms de di&aacute;metro y severos aquellos mayores de 5 cms de di&aacute;metro.</FONT></FONT>      <P><FONT FACE="Arial"><FONT SIZE=-1>Ocurren entre el 2.8% y el 22% de los procedimientos.</FONT></FONT>      <P><FONT FACE="Arial"><FONT SIZE=-1><B>Seudoaneurisma:</B> Tumoraci&oacute;n puls&aacute;til y dolorosa en sitio de punci&oacute;n, habitualmente con soplo a la auscultaci&oacute;n y que por eco doppler color se observa una cavidad extravascular ecol&uacute;cida con flujo en su interior, en comunicaci&oacute;n con el l&uacute;men arterial vecino y que presenta un flujo t&iacute;pico <B>(<A HREF="#fig2">Figura 2</A></B>). Su incidencia es del 0.3 al 6% de procedimientos, 3% en angioplast&iacute;as con bal&oacute;n y 6% en implante de stents coronarios.</FONT></FONT>      <P><FONT FACE="Arial"><FONT SIZE=-1><B>F&iacute;stula arteriovenosa:</B> Presencia a la auscultaci&oacute;n de un soplo continuo en sitio de punci&oacute;n y detecci&oacute;n por doppler de un jet de flujo continuo de alta velocidad entre arteria y vena femoral. Ocurre en el 0.1 al 2.1% de los pacientes. Habitualmente esta relacionado a una punci&oacute;n muy baja o muy medial, o una variante anat&oacute;mica en que la vena se encuentre anterior a la arteria y durante la punci&oacute;n es atravesada. Generalmente es de resoluci&oacute;n quir&uacute;rgica.</FONT></FONT>      <P><FONT FACE="Arial"><FONT SIZE=-1><B>Hematoma retroperitoneal:</B> Colecci&oacute;n liquida retroperitoneal en pacientes sometidos recientemente a punci&oacute;n arterial femoral que presentan distensi&oacute;n abdominal, dolor lumbar y disminuci&oacute;n de hematocrito, diagnosticado mediante ultrasonido o tomografia axial computarizada. Se incidencia es del 0.1 al 3.5% de los procedimientos, siendo mayor en los implantes de stent. Se relaciona predominantemente a una anticoagulaci&oacute;n excesiva y/o punciones excesivamente altas.</FONT></FONT>      <P><FONT FACE="Arial"><FONT SIZE=-1><B>Isquemia perif&eacute;rica distal a sitio de punci&oacute;n:</B> Ausencia de perfusi&oacute;n distal a zona de punci&oacute;n femoral con p&eacute;rdida de pulso distal, palidez o dolor, clasific&aacute;ndose como agudo (menor a 24 hs) o subagudo (entre las 24 hs posteriores al procedimiento y antes del alta hospitalaria) (<A HREF="#2">2</A>). Su incidencia oscila entre el 0.1 y el 0.3% de procedimentos, con una relaci&oacute;n directa al di&aacute;metro de introductor utilizado.</FONT></FONT>      <P><FONT FACE="Arial"><FONT SIZE=-1>Estas complicaciones vasculares se traducen de forma final en una mortalidad del 6.2% (<A HREF="#2">2</A>).</FONT></FONT>      ]]></body>
<body><![CDATA[<P><FONT FACE="Arial"><FONT SIZE=-1>Se han definido una serie de factores cl&iacute;nicos relacionados al riesgo de complicaciones vasculares como son la hipertensi&oacute;n arterial, obesidad, sujetos de baja talla y tratamiento anticoagulante al procedimiento (<A HREF="#4">4</A>).</FONT></FONT>      <P><FONT FACE="Arial"><FONT SIZE=-1><U>Entre los factores relacionados al procedimiento destaca: </U>n&uacute;mero de introductor utilizado, tiempo de duraci&oacute;n del procedimiento (47% de complicaciones en procedimientos de m&aacute;s de 2 horas), tiempo de permanencia del introductor (14% de pacientes con complicaciones, si el introductor de dejaba m&aacute;s de 24 horas), experiencia del personal que realiza la compresi&oacute;n, punci&oacute;n por debajo de la bifurcaci&oacute;n de la arteria femoral com&uacute;n, intensidad de tratamiento anticoagulante o antiagregante plaquetario.</FONT></FONT>      <P><FONT FACE="Arial"><FONT SIZE=-1>La evoluci&oacute;n natural del seudoaneurisma consiste en una tasa muy baja de cierre espont&aacute;neo, dolor inguinal progresivo y neuropat&iacute;a por compresi&oacute;n, as&iacute; como dilataci&oacute;n progresiva y rotura posterior (<A HREF="#5">5</A>). El tratamiento de los pseudoaneurismas tradicionalmente ha consistido en cirug&iacute;a correctiva del mismo, la cual debe realizarse de forma urgente en seudoaneurismas de m&aacute;s de 4 cms de di&aacute;metro y con crecimiento progresivo. Sin embargo en la &uacute;ltima d&eacute;cada han surgido reportes de numerosos grupos a nivel mundial que indican una tasa elevada de &eacute;xito y bajo porcentaje de complicaciones mediante el tratamiento no quir&uacute;rgico de esta complicaci&oacute;n mediante la compresi&oacute;n del cuello del seudoaneurisma guiado por ecocardiograf&iacute;a (<A HREF="#5">5</A>, <A HREF="#6">6</A>, <A HREF="#7">7</A>). Sin embargo en algunos centros que han realizado intentos terap&eacute;uticos con la compresi&oacute;n guiada por ecocardiograf&iacute;a, han tenido resultados desalentadores (<A HREF="#3">3</A>), demostrando una vez m&aacute;s la necesidad de una curva de aprendizaje en ciertos procedimientos diagn&oacute;sticos y terap&eacute;uticos utilizando a la ecocardiograf&iacute;a. Recientemente se ha descrito con gran &eacute;xito la inyecci&oacute;n de col&aacute;geno bovino guiado por ecocardiograf&iacute;a (98% de cierre) en pacientes en que la compresi&oacute;n del cuello guiada por eco ha sido fallida (<A HREF="#8">8</A>). Este col&aacute;geno bovino biodegradable induce la activaci&oacute;n y agregaci&oacute;n plaquetaria, libera factores de coagulaci&oacute;n y resulta en la formaci&oacute;n de fibrina y la subsecuente formaci&oacute;n de un trombo (<A HREF="#9">9</A>). Se prev&eacute; que esta nueva herramienta terap&eacute;utica har&aacute; menos probable la necesidad de cirug&iacute;a en estos pacientes.</FONT></FONT>      <P><FONT FACE="Arial"><FONT SIZE=-1>El caso descrito en este reporte demuestra la viabilidad de este tipo de tratamiento en nuestro medio y la necesidad de una mejor coordinaci&oacute;n entre las diferentes secciones de cardiolog&iacute;a de nuestros hospitales respecto al soporte que otras secciones del mismo servicio podr&iacute;an brindar en el diagn&oacute;stico y la implementaci&oacute;n de nuevos procedimientos terap&eacute;uticos en las complicaciones vasculares del cateterismo card&iacute;aco.</FONT></FONT>      <P><B><FONT FACE="Arial"><FONT SIZE=-1>Referencias</FONT></FONT></B>      <!-- ref --><P><A NAME="1"></A><FONT FACE="Arial"><FONT SIZE=-1>1- Winthrop PD, Malenka DJ, Ryan TJ, Shubrooks SJ, Oconnor JT, Robb JF, Farell KL, et al. Predicting vascular complications in percutaneus coronary interventions. Am Heart J 2003; 145: 1022-1029</FONT></FONT>    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741219&pid=S1409-4142200300030000900001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P><A NAME="2"></A><FONT FACE="Arial"><FONT SIZE=-1>2- Rimbau EM, Lozano P, G&oacute;mez A, Bethencourt A, G&oacute;mez F. Lesiones vasculares yatrog&eacute;nicas tras cateterismo card&iacute;aco. Rev Esp Cardiol 1998; 51: 750-755</FONT></FONT>    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741220&pid=S1409-4142200300030000900002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P><A NAME="3"></A><FONT FACE="Arial"><FONT SIZE=-1>3- Navarro F, I&ntilde;iguez A, C&oacute;rdoba M, Garcia S, G&oacute;mez A, Serrano C, De la Paz J, Serrano JM, Almeida P. Factores relacionados con la aparici&oacute;n de complicaciones vasculares perif&eacute;ricas tras procedimientos percut&aacute;neos. Rev Esp Cardiol 1997; 50: 480-490</FONT></FONT>    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741221&pid=S1409-4142200300030000900003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P><A NAME="4"></A><FONT FACE="Arial"><FONT SIZE=-1>4- Alfonso F, Macaya C, Goicolea J, I&ntilde;iguez A, Hernandez R, Ba&ntilde;uelos C, Alvarez R, Moreno R, Aroca M, Zarco P. Doppler codificado en color en el diagn&oacute;stico de las complicaciones vasculares tras el cateterismo card&iacute;aco. Rev Esp Cardiol 1992; 45:374-380</FONT></FONT>    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741222&pid=S1409-4142200300030000900004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P><A NAME="5"></A><FONT FACE="Arial"><FONT SIZE=-1>5- Vilacosta I, Villanueva MA, Castillo JA, Roll&aacute;n MJ, San Rom&aacute;n JA, Zamorano J, Dom&iacute;nguez L, Goicolea J, Alfonso F, Ba&ntilde;uelos C, Conde A, Sanchez-Harguindey L. Utilidad del eco-doppler color en el tratamiento de los seudoaneurismas femorales. Rev Esp Cardiol 1993; 46:319-321</FONT></FONT>    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741223&pid=S1409-4142200300030000900005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P><A NAME="6"></A><FONT FACE="Arial"><FONT SIZE=-1>6- Agarwal R, Agarwal SK, Roubi GS, Berland L, Cox DA, Lyer SS et al. Clinically guided closure of femoral arterial pseudoaneurisms complicating cardiac catheterization and coronary angioplasty. Cathet Cardiovasc Diagn 1993; 30:96-100</FONT></FONT>    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741224&pid=S1409-4142200300030000900006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P><A NAME="7"></A><FONT FACE="Arial"><FONT SIZE=-1>7- Hajarizadeh H, LaRosa CR, Cardullo P, Rohrer MJ, Cutler BS. Ultrasound-guided compression of iatrogenic femoral pseudoaneurisms: failure, recurrence and long term results. J Vasc Surg 1995; 22:425-433</FONT></FONT>    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741225&pid=S1409-4142200300030000900007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P><A NAME="8"></A><FONT FACE="Arial"><FONT SIZE=-1>8- Hamraoui K, Ernst S, van Dessel P, Kelder JC, ten Berg JM, Suttorp MJ, Jaarsma W, Plokker TH. Efficacy and safety of percutaneous treatment of iatrogenic femoral artery pseudoaneurysm by biodegradable collagen injection. J Am Coll Cardiol 2002; 39:1297-1304</FONT></FONT>    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741226&pid=S1409-4142200300030000900008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><P><A NAME="9"></A><FONT FACE="Arial"><FONT SIZE=-1>9- Silber S. Hemostasis success rates and local complications with collagen after femoral access for cardiac catheterization. Analysis of 6007 published patients. Am Heart J 1998; 135:152-156</FONT></FONT>    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=741227&pid=S1409-4142200300030000900009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><P><A NAME="*A"></A><FONT FACE="Arial"><FONT SIZE=-1><A HREF="#*R">*</A> Centro Cardiol&oacute;gico Integral.San Jos&eacute;,Costa Rica</FONT></FONT>     <BR><FONT FACE="Arial"><FONT SIZE=-1>&nbsp;</FONT></FONT>      <P><FONT FACE="Arial"><FONT SIZE=-1>&nbsp;</FONT></FONT>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Winthrop]]></surname>
<given-names><![CDATA[PD]]></given-names>
</name>
<name>
<surname><![CDATA[Malenka]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
<name>
<surname><![CDATA[Ryan]]></surname>
<given-names><![CDATA[TJ]]></given-names>
</name>
<name>
<surname><![CDATA[Shubrooks]]></surname>
<given-names><![CDATA[SJ]]></given-names>
</name>
<name>
<surname><![CDATA[Oconnor]]></surname>
<given-names><![CDATA[JT]]></given-names>
</name>
<name>
<surname><![CDATA[Robb]]></surname>
<given-names><![CDATA[JF]]></given-names>
</name>
<name>
<surname><![CDATA[Farell]]></surname>
<given-names><![CDATA[KL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Predicting vascular complications in percutaneus coronary interventions]]></article-title>
<source><![CDATA[Am Heart J]]></source>
<year>2003</year>
<volume>145</volume>
<page-range>1022-1029</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rimbau]]></surname>
<given-names><![CDATA[EM]]></given-names>
</name>
<name>
<surname><![CDATA[Lozano]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Gómez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Bethencourt]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Gómez]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Lesiones vasculares yatrogénicas tras cateterismo cardíaco]]></article-title>
<source><![CDATA[Rev Esp Cardiol]]></source>
<year>1998</year>
<volume>51</volume>
<page-range>750-755</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Navarro]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Iñiguez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Córdoba]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Garcia]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Gómez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Serrano]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[De la Paz]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Serrano]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Almeida]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Factores relacionados con la aparición de complicaciones vasculares periféricas tras procedimientos percutáneos]]></article-title>
<source><![CDATA[Rev Esp Cardiol]]></source>
<year>1997</year>
<volume>50</volume>
<page-range>480-490</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Alfonso]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Macaya]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Goicolea]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Iñiguez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Hernandez]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Bañuelos]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Alvarez]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Moreno]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Aroca]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Zarco]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Doppler codificado en color en el diagnóstico de las complicaciones vasculares tras el cateterismo cardíaco]]></article-title>
<source><![CDATA[Rev Esp Cardiol]]></source>
<year>1992</year>
<volume>45</volume>
<page-range>374-380</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vilacosta]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Villanueva]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Castillo]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Rollán]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[San Román]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Zamorano]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Domínguez]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Goicolea]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Alfonso]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Bañuelos]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Conde]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Sanchez-Harguindey]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Utilidad del eco-doppler color en el tratamiento de los seudoaneurismas femorales]]></article-title>
<source><![CDATA[Rev Esp Cardiol]]></source>
<year>1993</year>
<volume>46</volume>
<page-range>319-321</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Agarwal]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Agarwal]]></surname>
<given-names><![CDATA[SK]]></given-names>
</name>
<name>
<surname><![CDATA[Roubi]]></surname>
<given-names><![CDATA[GS]]></given-names>
</name>
<name>
<surname><![CDATA[Berland]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Cox]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
<name>
<surname><![CDATA[Lyer]]></surname>
<given-names><![CDATA[SS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinically guided closure of femoral arterial pseudoaneurisms complicating cardiac catheterization and coronary angioplasty]]></article-title>
<source><![CDATA[Cathet Cardiovasc Diagn]]></source>
<year>1993</year>
<volume>30</volume>
<page-range>96-100</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hajarizadeh]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[LaRosa]]></surname>
<given-names><![CDATA[CR]]></given-names>
</name>
<name>
<surname><![CDATA[Cardullo]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Rohrer]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Cutler]]></surname>
<given-names><![CDATA[BS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ultrasound-guided compression of iatrogenic femoral pseudoaneurisms: failure, recurrence and long term results]]></article-title>
<source><![CDATA[J Vasc Surg]]></source>
<year>1995</year>
<volume>22</volume>
<page-range>425-433</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hamraoui]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Ernst]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[van Dessel]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Kelder]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[ten Berg]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Suttorp]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Jaarsma]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Plokker]]></surname>
<given-names><![CDATA[TH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Efficacy and safety of percutaneous treatment of iatrogenic femoral artery pseudoaneurysm by biodegradable collagen injection]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2002</year>
<volume>39</volume>
<page-range>1297-1304</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Silber]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Hemostasis success rates and local complications with collagen after femoral access for cardiac catheterization. Analysis of 6007 published patients]]></article-title>
<source><![CDATA[Am Heart J]]></source>
<year>1998</year>
<volume>135</volume>
<page-range>152-156</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>