<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0001-6002</journal-id>
<journal-title><![CDATA[Acta Médica Costarricense]]></journal-title>
<abbrev-journal-title><![CDATA[Acta méd. costarric]]></abbrev-journal-title>
<issn>0001-6002</issn>
<publisher>
<publisher-name><![CDATA[Colegio de Médicos y Cirujanos de Costa Rica]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0001-60022023000200085</article-id>
<article-id pub-id-type="doi">10.51481/amc.v65i2.1220</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Comprobación del control automático de exposición en el tomógrafo Canon Aquilion ONE]]></article-title>
<article-title xml:lang="en"><![CDATA[Verification of the automatic exposure control on the Canon Aquilion ONE tomograph]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[González-López]]></surname>
<given-names><![CDATA[Dagoberto]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Camacho-Soto]]></surname>
<given-names><![CDATA[José Alonso]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Salvador-Hernández]]></surname>
<given-names><![CDATA[Lourdes]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Santos-Gutiérrez]]></surname>
<given-names><![CDATA[Fredys]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Caja Costarricense de Seguro Social. Hospital México Servicio de Medicina Nuclear]]></institution>
<addr-line><![CDATA[ San José]]></addr-line>
<country>Costa Rica</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Caja Costarricense de Seguro Social. Dirección de Administración de Proyectos Especiales, Ambiente y Seguridad Humana Área de Control de Calidad y Protección Radiológica]]></institution>
<addr-line><![CDATA[ San José]]></addr-line>
<country>Costa Rica</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,Caja Costarricense de Seguro Social Área de Control de Calidad y Protección Radiológica. Dirección de Administración de Proyectos Especiales, Ambiente y Seguridad Humana.]]></institution>
<addr-line><![CDATA[ San José]]></addr-line>
<country>Costa Rica</country>
</aff>
<aff id="Af4">
<institution><![CDATA[,Caja Costarricense de Seguro Social. Dirección de Administración de Proyectos Especiales, Ambiente y Seguridad Humana. Área de Control de Calidad y Protección Radiológica]]></institution>
<addr-line><![CDATA[ San José]]></addr-line>
<country>Costa Rica</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2023</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2023</year>
</pub-date>
<volume>65</volume>
<numero>2</numero>
<fpage>85</fpage>
<lpage>91</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_arttext&amp;pid=S0001-60022023000200085&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_abstract&amp;pid=S0001-60022023000200085&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.sa.cr/scielo.php?script=sci_pdf&amp;pid=S0001-60022023000200085&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen Dado el uso incrementado de la tomografía computarizada en la Caja Costarricense del Seguro Social durante los últimos 10 años, se ha vuelto cada vez más importante obtener imágenes de la calidad diagnóstica requerida con la mínima dosis de radiación posible al paciente. Para lograr esto, en los sistemas de tomografía computarizada se utiliza, rutinariamente, el control automático de exposición, el cual modula la corriente del tubo según la atenuación del haz que produce el paciente y que se obtiene en el escanograma.  Objetivo  Comprobar el funcionamiento del control automático de exposición de un tomógrafo Canon Aquilion ONE en la dosis suministrada al paciente y verificar la importancia de realizar un simple o doble escanograma para diferentes protocolos clínicos.  Métodos  Se analizó el comportamiento de la dosis, el ruido y la intensidad de la corriente obtenida en un maniquí con diferentes secciones elípticas que varían sus dimensiones en los ejes X-Y. Se determinó el producto dosis longitud en diferentes protocolos clínicos con el control automático de exposición activado debido a un simple o doble escanograma.  Resultados  Para intensidades de corrientes fijas, a medida que aumenta el tamaño de cada sección del maniquí, la dosis se reduce, aproximadamente hasta el 72% y, cuando disminuye el tamaño de cada sección, mejora hasta en un 21% la calidad de la imagen debido a la reducción del ruido.  Conclusiones  Se pudo observar que, a pesar de que las dosis para localización son bajas, la utilización de un simple escanograma, en la mayoría de los protocolos, no solo permite reducir la dosis suministrada al paciente, sino también efectuar menor cantidad de disparos en el equipo e incrementar la vida útil del tubo de rayos X, pues el aporte de un segundo escanograma no representa un impacto significativo en la calidad de imagen.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract Given the increased use of computed tomography in the Costa Rican Social Security Fund during the last 10 years, it has become increasingly important to obtain images of the required diagnostic quality with the minimum radiation dose to the patient. To achieve this, computed tomography systems routinely use automatic exposure control, modulating the tube current according to the attenuation of the beam produced by the patient and obtained on scanogram.  Aim  Check the operation of the automatic exposure control of a Canon Aquilion ONE scanner at the dose delivered to the patient and to verify the importance of performing a single or double scanogram for different clinical protocols.  Methods : The behavior of the dose, the noise and the intensity of the current was analyzed in a phantom with different elliptical sections that vary their dimensions in the X-Y axes. The dose-length product was determined in different clinical protocols with the automatic exposure control activated due to a single or a double scanogram.  Results  For fixed current intensities, as the size of each section of the phantom increases, the dose is reduced, approximately, up to 72% and when the size of each section decreases, the quality of image improves, due to noise reduction, up to 21%.  Conclusions  It was observed that, despite the fact that the doses for localization are low, the use of a simple scanogram in most protocols not only reduces the dose to the patient, but also makes fewer shots in the equipment and increases the useful life of the X-ray tube, since the contribution of a second scanogram does not represent a significant impact on image quality.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Tomografía computarizada]]></kwd>
<kwd lng="es"><![CDATA[control automático de exposición]]></kwd>
<kwd lng="es"><![CDATA[calidad de imagen]]></kwd>
<kwd lng="es"><![CDATA[dosis]]></kwd>
<kwd lng="en"><![CDATA[Computerized tomography]]></kwd>
<kwd lng="en"><![CDATA[automatic exposure control]]></kwd>
<kwd lng="en"><![CDATA[image quality]]></kwd>
<kwd lng="en"><![CDATA[dose]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<label>1.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McCollough]]></surname>
<given-names><![CDATA[CH]]></given-names>
</name>
<name>
<surname><![CDATA[Bruesewitz]]></surname>
<given-names><![CDATA[MR]]></given-names>
</name>
<name>
<surname><![CDATA[Kofler]]></surname>
<given-names><![CDATA[JM, Jr]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[CT dose reduction and dose management tools: overview of available options.]]></article-title>
<source><![CDATA[Radiographics]]></source>
<year>2006</year>
<volume>26</volume>
<page-range>503-12</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kuttner]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Bujila]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Kortesniemi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Andersson]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Kull]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Helge]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A proposed protocol for acceptance and constancy control of computed tomography systems: a Nordic Association for Clinical Physics (NACP) work group report.]]></article-title>
<source><![CDATA[Acta Radiol]]></source>
<year>2013</year>
<volume>54</volume>
<page-range>188-98</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Iball]]></surname>
<given-names><![CDATA[GR]]></given-names>
</name>
<name>
<surname><![CDATA[Moore]]></surname>
<given-names><![CDATA[AC]]></given-names>
</name>
<name>
<surname><![CDATA[Crawford]]></surname>
<given-names><![CDATA[EJ.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A routine quality assurance test for CT automatic exposure control systems.]]></article-title>
<source><![CDATA[Journal of Applied Clinical Medical Physics]]></source>
<year>2016</year>
<volume>17</volume>
</nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wood]]></surname>
<given-names><![CDATA[TJ]]></given-names>
</name>
<name>
<surname><![CDATA[Moore]]></surname>
<given-names><![CDATA[CS]]></given-names>
</name>
<name>
<surname><![CDATA[Stephens]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Saunderson]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Beavis]]></surname>
<given-names><![CDATA[AW.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A practical method to standardize and optimize the Philips DoseRight 2.0 CT automatic exposure control system.]]></article-title>
<source><![CDATA[J. Radiol. Prot]]></source>
<year>2015</year>
<volume>35</volume>
<page-range>495-506</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>