vol.24 número2El efecto de la velocidad de rotación de XP-endo Shaper sobre los desechos extruídos apicalmente durante los procedimientos de endodoncia: un estudio in vitroCaracterización de manifestaciones alérgicas de profesionales en Odontología índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Odovtos International Journal of Dental Sciences

versión On-line ISSN 2215-3411versión impresa ISSN 1659-1046

Resumen

ŞIşMANOğLU, Soner  y  SENGEZ, Görkem. Effects of acidic beverages on color stability of bulk-fill composites with different viscosities. Odovtos [online]. 2022, vol.24, n.2, pp.90-99. ISSN 2215-3411.  http://dx.doi.org/10.15517/ijds.2022.49149.

The aim of this in vitro study is to investigate the effects of acidic beverages on the discoloration of bulk-fill composites with different viscosities. 144 disc-shaped specimens (8mm diameter × 2mm thick) were prepared from four different composite resins including a nanohybrid (Filtek Ultimate), two packable bulk- fill (Filtek Bulk Fill, Tetric N Ceram Bulk Fill), and a flowable bulk-fill composite (Tetric N Flow Bulk Fill). The specimens of each group were divided into 3 subgroups and submerged in distilled water, orange juice and coke (n=12). Color difference (ΔE) were measured using CIELab color space and a compact spectrophotometer (VITA Easyshade) at baseline and after 30 days of immersion. Data were analyzed using two- way ANOVA and Tukeys HSD post-hoc tests (P<0.05). Two-way ANOVA revealed that both material type and staining solution significantly influenced ΔE values (P<0.001). Immersion in orange juice resulted in greater and significant discoloration over time in comparison to distilled water and coke (P<0.05). Tetric N Ceram (ΔE=7.0) and Tetric N Flow (ΔE=7.7) bulk-fill restoratives showed highest color change values after 30 days of immersion in orange juice. This study suggests that a discoloration above the clinically acceptable threshold (ΔE>2.7) was observed for all bulk-fill composites tested. It can be speculated that orange juice has a more negative effect on the color stability compared to coke. Additionally, flowable bulk-fill composite was more prone to discoloration than condensable bulk-fill composites.

Palabras clave : Composite resins; Color; Dental filling; Dental materials; Dentistry; Food coloring agents.

        · resumen en Español     · texto en Inglés     · Inglés ( pdf )