SciELO - Scientific Electronic Library Online

 
vol.24 número1Efecto de diferentes agentes antioxidantes en la resistencia a la microtracción de la resina compuesta al esmalte blanqueadoPropiedades físico-químicas y actividad antibiofilm del cemento de silicato tricálcico y su asociación con cetrimida índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Odovtos International Journal of Dental Sciences

versión On-line ISSN 2215-3411versión impresa ISSN 1659-1046

Resumen

DEğIRMENCI, Alperen  y  BILGILI CAN, Dilber. Pre-Heating effect on the microhardness and depth of cure of Bulk-Fill composite resins. Odovtos [online]. 2022, vol.24, n.1, pp.99-112. ISSN 2215-3411.  http://dx.doi.org/10.15517/ijds.2021.47209.

The aim of this study was to investigate the effect of preheating three bulk-fill and one conventional composite resin on the Vickers microhardness and depth of cure of these composites. In this study, three bulk-fill composites- SDR Plus (SDR), Estelite BULK FILL Flow (EST), Admira® Fusion x-tra (AFX), and one conventional composite resin G-ænial POSTERIOR (GP) were used as the control group. The samples were obtained at room temperature (24°C) and at 55°C in T2 mode after being placed in a heating device for 10 minutes. The samples were divided into eight groups (n=10) according to the type of material and heating process that was utilized (preheated and nonheated). All samples were tested with a Vickers microhardness (VHN) tester on the bottom and top surfaces. The first measurements were obtained at baseline; the second set of measurements was performed after the samples were stored in distilled water at 37°C for 24 hours. The depth of cure was calculated using a bottom/top hardness ratio of measurements. Statistical analysis was performed utilizing the SPSS V23 and Shapiro-Wilk tests. Lastly, the Duncan test was used for multiple comparisons (p<0.05). While the VHN increased after the preheating procedure in bulk-fill composites, it decreased in GP. There was no difference between the baseline and the 24-hour VHN values in SDR and GP. After 24 hours, while the VHN of EST increased, the VHN of AFX decreased. There was no difference between the hardness ratios of the AFX and EST samples (p<0.001) and hardness ratios were greater than GP and SDR. When comparing the baseline and the 24- hour values, the VHN depended on the type of materials. Sufficient curing depth was obtained in all groups with a thickness of 2mm.

Palabras clave : Bulk-fill composite; Preheating; Vickers microhardness; Depth of cure; Microhybrid composite; Ormocer.

        · resumen en Español     · texto en Inglés     · Inglés ( pdf )