SciELO - Scientific Electronic Library Online

 
vol.31 número4Development of a fixed-wing UAS platform for photogrammetric applicationsMicroorganisms of the marine corridor Isla del Coco-Galapagos: functional and species diversity índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Revista Tecnología en Marcha

versão On-line ISSN 0379-3982versão impressa ISSN 0379-3982

Resumo

ROJAS-ARRIETA, Karla; SALAZAR-CHACON, Yajaira; ROJAS-MARTINEZ, José Luis  e  BORBON, Henry. Validation of a post - column reactor liquid chromatography and fluorescence detection method for the determination of paralytic shellfish poisoning toxins in bivalve molluscs from Costa Rica. Tecnología en Marcha [online]. 2018, vol.31, n.4, pp.142-156. ISSN 0379-3982.  http://dx.doi.org/10.18845/tm.v31i4.3973.

Chromatographic and extraction conditions were implemented and validated for the determination of twelve paralytic toxins (PSP) in bivalves, including STX’s (saxitoxins), GTX’s (gonyautoxins) and C’s (N-sulfocarbamoyl gonyautoxins). The extraction method of Rourke et al. (1) was tested and modified using an acid extraction in 0.1 M HCl and 30 m/v trichloroacetic acid in the purification step. The chromatographic methods proposed by Rourke et al. (1) and Franco and Fernández (2) were evaluated. The validation was performed for the first method mentioned (1); a gradient program is established for the separation of STX’s and GTX’s toxins, and an isocratic method for the separation of C’s. The established method was further validated by determining the correlation coefficient (R) (0.995-1.000), coefficient of determination (R2) (0.989-1.000), linear range (53.7-926.6 μg STX diHCl equivalents/100 g), sensitivity (4.32-60.32 LU (μmol/L)-1), recovery percentage (58-115%), coefficient of variation (2-17%) for instrumental repeatability and (2-16%) for methodological repeatability, sensitivity (limits of detection (LODs)): 1.1-8.5 μg/100g and limits of quantification (LOQs)): 1.60-12.6 μg/100g. The application of this method proved good performance and capability for simultaneous determination of PSP toxins in bivalve molluscs.

Palavras-chave : Paralytic shellfish poisoning (PSP); bivalves; high performance liquid chromatography- fluorescence detector (HPLC-LF); post column reactor.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )